Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Triggers on any active alarm set on the Vantage Pro or Pro2 console/
Envoy. Functions according to settings listed below:
Duration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 255 minutes (user selectable). Determines how long the alarm 
output should stay active once it is triggered. Default = 10 minutes
Reactivation  . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 255 minutes (user selectable). Determines how long to leave the 
alarm output deactivated once it is deactivated. Default = 0.
Pulse Width. . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 9999 milliseconds (user selectable). Default = 2000 milliseconds 
(2 seconds).
Activation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous or Pulse (1-time) (user selectable). Determines whether 
a pulse for alarm activation is continuous throughout the activation 
time or a one time pulse. Pulsed relay oriented devices will require the 
one-time pulse. Default = Continuous
Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normally Open or Normally Closed (user-selectable). Determines 
whether the circuit stays open or closed when no alarms are active. 
The opposite behavior occurs for an active alarm condition. Normally 
Closed is the most typical operation for Irrigation controller use. 
Default = Normally Closed.
Test Mode Function  . . . . . . . . . . . . . . . . . . . . Available. Continuous, Open, or Closed circuit (user-selectable).
Residential Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Used with a Residential Irrigation System Controller to inhibit the 
watering cycle. This type of sprinkler controller will be what is typically 
installed by most homeowners and will have inputs for a Common and 
in many cases a Rain Sensor. The following functions are available 
for this mode only:
Irrigation Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 to 255 hours (user-selectable). Indicates the number of hours 
between entire watering cycles, which are the period of time it takes 
for all programmed cycles on the Irrigation controller to start, finish 
and then begin again. Default = 24 (daily watering cycle).
Rain - ET Threshold . . . . . . . . . . . . . . . . . . . . . . . . . -9.99" to +9.99", (253.7 mm) (user-selectable) Difference between 
the Total Rainfall minus the Total Evapotranspiration (ET) over the 
Irrigation Cycle (see above). Update Interval = 1 hour. Default = 0.
Rain Rate Cut-Off  . . . . . . . . . . . . . . . . . . . . . . . . . . 0.00" to 0.99"/hour (25.1 mm/hour) or off (user-selectable). Used to 
inhibit the irrigation cycle during heavy rain situations. Default = 0.30"/
hour (7.6 mm/hour). This function can be disabled in the streaming 
data utility bundled with WeatherLink 5.6 or later.
P a c k a g e   D i m e n s i o n s
Product #
Package Dimensions
(Width x Height x Depth) 
Package Weight
UPC Codes
6510SER
6.00" x 9.00" x 1.63" 
(152 mm x 229 mm x 42 mm)
8.0 oz. (0.23 kg)
011698 00726 4
6510USB
011698 00727 1
6540
9.6 oz. (0.28 kg)
011698 00736 3
6544
10.3 oz. (0.29 kg)
011698 00820 9
6550
8.6 oz. (0.24 kg)
011698 00737 0
6560
9.9 oz. (0.29 kg)
011698 00738 7