266X CompactFlash Card 
 
Transcend Information Inc.
 
 
80
  SMART Data Structure 
BYTE 
F / V 
Decription 
0-1 
Revision code 
2-361  
Vendor specific 
362  
Off line data collection status  
363  
Self-test execution status byte 
364-365 
Total time in seconds to complete off-line data collection activity 
366  
Vendor specific 
367  
Off-line data collection capability 
368-369 
SMART capability 
370  
Error logging capability  
7-1 Reserved  
0  1=Device error logging supported 
371  
Vendor specific 
372  
Short self-test routine recommended polling time (in minutes) 
373  
Extended self-test routine recommended polling time (in minutes) 
374  
Conveyance self-test routine recommended polling time (in minutes) 
375-385  
Reserved 
386-395 
Date Code  
396 
Number of MU in device (0~n) 
397+(n*6) 
MU number 
398+(n*6) 
MU data block 
400+(n*6) 
MU spare block 
401+(n*6) 
Init. Bad block 
402+(n*6) 
Last Defect Bad block ( Newest state) 
511  
Data structure checksum 
F=the content of the byte is fixed and does not change. 
V=the content of the byte is variable and may change depending on the state of the device or 
the commands executed by the device. 
X=the content of the byte is vendor specific and may be fixed or variable. 
R=the content of the byte is reserved and shall be zero. 
* 4 Byte value : [MSB] [2] [1] [LSB] 
Above technical information is based on CFA standard data and tested to be reliable. However, Transcend makes no 
warranty,  either  expressed  or  implied,  as  to  its  accuracy  and  assumes  no  liability  in  connection  with  the  use  of  this 
product. Transcend reserves the right to make changes in specifications at any time without prior notice.
 