Accu-Tech 048K88-61130-29 Benutzerhandbuch
Part Number: 048K88-61130-29
Cross Section of Part Number: 048K88-61130-29
Ripcord
Flame-Retardant
Outer Jacket
Dielectric Strength
Dielectric Strength
Members
Ripcord
Ripcord
Tight-Buffered
Fiber
Dielectric Central
Dielectric Central
Element
Flame-Retardant
Flame-Retardant
Subunit Jacket
210.8297
Corning Cable Systems MIC
®
Unitized Plenum Cables
are designed for use in plenum, riser and general pur-
pose environments for intrabuilding backbone installa-
tions. These multifiber cables use individually jacketed
900 μm TBII
®
Buffered Fibers enabling easy, consistent
stripping and facilitating termination. The stranded sub-
units of six or 12 fibers allow quick and easy identification
and are surrounded by dielectric strength members and
protected by a flame -retardant outer jacket.
The all -dielectric cable construction requires no ground-
The all -dielectric cable construction requires no ground-
ing or bonding, making these cables ideal for routing in-
side buildings including riser shafts, to the telecommuni-
cations rooms and workstations. The MIC Unitized Riser
Cables meet the application requirements of the National
Electrical Code
®
(NEC
®
) Article 770 and the ICEA S -
83 -596 test criteria. They are OFNP and FT -6 listed.
This cable is available in 12 different jacket colors - blue,
This cable is available in 12 different jacket colors - blue,
orange, green, brown, slate, white, red, black, yellow,
purple, rose and aqua. The colored jacket allows for easy
visual identification of the cables. The standard jacket
color will be determined by the dominant fiber type in
the cable and will use the standard part numbers shown
here. Contact Customer Care at 1 -800 -743 -2675 to order
other color options.
Corning
Cable
Features and Benefits
900 µm TBII
®
Buffered Fibers
Easy, consistent stripping
6- or 12-fiber jacketed subunits
6- or 12-fiber jacketed subunits
Quick and easy identification
All-dielectric construction
All-dielectric construction
Requires no grounding or bonding
Flame-retardant jacket
Flame-retardant jacket
Rugged and durable
1
1
Standards
Approval and Listings
National Electrical Code
®
(NEC
®
) OFNP, CSA FT-6,
ICEA S-83-596
Flame Resistance
NFPA 262 (for plenum, riser
and general building appli-
cations)
26.61
115
0
False
MIC
®
Unitized Tight-Buffered Cable, Plenum
48 F, 62.5 µm multimode (OM1)
Product Specification 048K88-61130-29_NAFTA_AEN
Page 1 | Revision date 2012-08-25