Trion Air Boss ATS Benutzerhandbuch

Seite von 16
3
• Trion Quality
The same high quality that Trion provides on ALL of the US Navy submarine fleet
since 1947 as a sole supplier of air cleaning equipment to the world’s navies.
• NFPA Qualified
Designed to NFPA 96 standards for kitchen exhaust.
• ETL Listed
ETL approved to UL standard 867.
• Sectional Design
Built-up design allows units to be tailored to your exact requirements.
• Smoke and Odor Control
Components effectively remove both liquid and solid particulate, as well as gas and odor.
• Complete System Design
One central system to effectively treat virtually any application for kitchen or industrial exhaust air.
• High Efficiency Cleaning
Up to 99% efficient, per DOP or ASHRAE test methods.
• Spiked Ionizer Design
Eliminates common wire breakage and replacement, as seen in wire and other ionizer cell designs.
• Heavy Duty Cell Design
The most durable and efficient cell design on the market insures long term performance and reliability.
• Automatic Cleaning
Programmable Logic Controller (PLC) automates the cleaning process, which reduces
maintenance costs and insures efficient air cleaning at all times.
• Simple to Service
Designed for easy serviceability from either side of cabinet, as specified.
• Optional Fire Suppression
Available on all systems to meet your specific requirements.
• Ease of Installation
System design makes installation simple and requires no field assembly. Just attach your
ductwork, electrical connection and plumbing, and it’s done.
Typical System Arrangements
The ATS units readily adapt to the
various air collection methods.
Feature/Benefits
• Customized for specific applications
• Effective on airborne solids, liquids
and odors
• Available in various capacity ranges
• Factory assembled, built-up construction
• Integral automatic cleaning system
• Optional fire suppression system
• ETL listed
• Designed for: simplified installation,
ease in service, NFPA 96 standards
ATS Applications
Oil Mist:
Machine Shops
Cold Heading
Screw Machines
Foundry
Presses
Machining Centers
Heat Treating
Tenter Frames
Smoke:
Welding
Presses/Forging
Curing
Rubber
Manufacturing
Plasticisers
Heat Treating
Kitchen Exhaust:
Grease
Smoke
Odors
Wood-fired
Cookers
HVAC:
Clean Rooms
Return Air
Outside/Makeup Air
Lounges
Bars
Smoking Rooms
Casinos
Indoor Gun Ranges
Return 
Air
Make-up 
Air
Tempering 
Coils
EAC with 
Prefilters
Conditioning 
Coils
Clean 
Conditional 
Air
System 
Blower
Fugitive Contaminate - Multiple Overhead
Discharge through Cental Trunk Line
Multiple Source Captured Contaminate
Hooded to Main Trunk Line
Multiple Source Captured Contaminate
Hooded to Common Mixing Plenum
Central System
Kitchen Exhaust
(Weatherproof)
Fugitive Contaminate - Low Column
Ducted Discharge