TROUBLESHOOTING
 WARNING: Turn off and unplug fireplace and let cool before servicing. 
Only a qualified service person should service and repair fireplace.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
 All troubles hooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor  electrode  positioned 
wrong
6. Ignitor electrode broken
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control  knob  not  in  PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air in gas lines when installed
5. Depleted gas supply (propane/
LP only)
6. ODS/pilot is clogged
7. Gas  regulator  setting  is  not 
correct
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Replace ignitor cable
4. Replace piezo ignitor 
5. Replace pilot assembly
6. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP gas 
company
6. Clean ODS/pilot (see Cleaning 
and Maintenance, page 27) or 
replace ODS/pilot assembly
7. Replace gas regulator
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot
When ignitor button is pressed, 
there is spark at ODS/pilot but 
no ignition