Installing Wireless Zones 
 
General Information 
Zones: The control supports up to 24 wireless zones using 5800 Series transmitters, and up to 16 
wireless buttons.  
Range: The built-in RF receiver can detect signals from wireless transmitters within a nominal 
range of 200 feet. 
Transmitters: 5800 Series transmitters have built-in serial numbers that must be entered into the 
system using the 
✻56 or ✻83 interactive mode, or input to the control via the downloader. 5800 
Series transmitters (except the 5800RL and 5827, described separately) do not have DIP switches. 
Each transmitter's zone number is programmed into the system in 
✻56 mode. Some transmitters, 
such as the 5816 and 5817, can support more than one "zone" (referred to as loops or inputs). On the 
5816, for example, the wire connection terminal block is loop 1,the reed contact is loop 2. Each loop 
must be assigned a different zone number.  
 
 
UL 
The 5816 and 5817 Transmitters do not have EOL supervision of their loop wiring. Therefore, for 
UL Household Burglary installations, the loop wiring may not exceed 3 feet. 
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5804WATCH, 5814, 5816TEMP, 
5819, 5819S(WHS & BRS), and 5850(GBD) transmitters are not intended for any UL installations.
 
 
For button transmitters (RF "keys") such as the 5804 and 5801, you must assign a unique zone 
number to each individual button used on the transmitter.  Each button on the transmitter also has 
a pre-designated loop or input number, which is automatically displayed. 
 
 
House Identification  
If you are using a 5804BD/5804BDV, or 5827 Wireless Keypad with 
the system, you must program a House ID Code (01–31) in field 
✻24 
to establish proper communication, and the keypad must be set to 
the same ID. House ID 00 disables all wireless keypads. An RF 
House ID is not necessary for other 5800 Series transmitters; the 
entry should be left at “00” (default) in those cases. The 5827 reports 
low battery status as zone “00”. 
Transmitter Supervision 
Except for some transmitters/keypads that may be carried off-
premises (5804, 5804BD, 5804BDV, 5804E, 5804WATCH, and 
5827), each transmitter is supervised by a check-in signal that is 
sent to the receiver at 70–90 minute intervals. If at least one check-
in is not received from each supervised transmitter within a 12-
hour period, the "missing" transmitter number(s) and "FAULT" will 
be displayed. The supervision for a particular transmitter in the 
system that may also be carried off the premises (5801, 5802MN) 
may be turned off by entering it as a "UR" (unsupervised RF) type, 
as described in the 
56 Enhanced Zone Programming Mode section. 
5800 Series transmitters have built-in tamper protection and will 
annunciate as a fault condition if covers are removed. 
 
••
••
• •
• •
•••
5806/5807/5808
5890 / 5890PI
5816
5827
5804BD/5804BDV
01009-010-V1
1
2
3
4
5
6
7
8
9
0
*
#
 
Transmitter Input Types 
Each of the following transmitters has one or more unique factory-assigned input (loop) ID codes. 
Each of the inputs requires a programming zone 
(e.g., a 5804's four inputs require four button zones)
.  
Transmitters can be entered as one of the following types 
(see transmitter’s instructions for appropriate 
input type)
 
Type Description 
"RF" (Supervised RF)  
Sends periodic check-in signals, as well as fault, restore, and low battery signals. The 
transmitter must remain within the receiver's range. 
"UR" (Unsupervised RF) 
Sends all the signals that the "RF" type does, but the control does not supervise the 
check-in signals. The transmitter may therefore be carried off-premises. 
"BR" (Unsupervised Button RF) 
These only send fault signals. They do not send low battery signals until they are 
activated.  The transmitter may be carried off-premises.
 