Honeywell ADEMCO LYNXR Series Benutzerhandbuch

Seite von 72
 
–45– 
Remote Programming/Control 
(Downloading) 
General Information 
The control panel can be remotely programmed from an IBM-compatible Personal Computer (PC), a HAYES 
Modem, and ADEMCO’s Compass Downloader for Windows (as specified below).  
U
U
U
ULLLL 
Downloading may only be performed if a technician is at the site. 
Multiple security levels protect remote programming against compromise by attempts to defeat the system. 
1. Security Code Handshake: An 8-digit download ID code must be matched between the Control and 
downloader. 
2.  Site-Initiated Remote Programming: The installer or subscriber initiates the call from the subscriber 
premises (by entering Installer Code + # + 1) while disarmed. All parameters can then be downloaded via 
the phone lines using a personal computer. 
3. Station-Initiated Remote Programming: The operator calls the site from your office to initiate the 
download call. The Control hangs up and then calls back the PC via the preprogrammed telephone 
number. The unit can then be uploaded, downloaded, or controlled from your office. 
4. Telco Handoff: The installer or subscriber performs a download session on the call initiated from the 
site or from local laptop computer (by entering Installer or Master Code + # + 1 at the control panel). 
5. Data Encryption: Data passed between the PC and the Control is encrypted for security so that it is 
very difficult for a foreign device tapped into the phone line to take over communication and substitute 
system-compromising information. 
Equipment required to download to a system at the premises 
•   An IBM PC compatible computer and appropriate interconnecting cables. 
•  Either a HAYES brand SMARTMODEM 1200 (Level 1.2 or higher external or Level 1.1 or higher [with 4 
position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 
Plus FAX96, or an Ademco CIA Modem. 
•  Compass Downloader for Windows (at revision level supporting LYNXR, LYNXR24 or LYNXR-EN). 
Initial Download: Enter Installer Code + # + 5. This sets field 
95 to 4 rings, and system to “no call-back” 
option. The download computer can then call the subscriber, make connection, and download all 
programming data. 
 
Flexible Callback: If enabled in field 
93, the download operator can temporarily change the last 1, 2, or 3 
digits (depending on selection) of the call back number. This allows the control to call back a computer other 
than the one programmed, which may be helpful at times of high computer traffic. See field 
93 for a full 
description. 
 
Remote Programming Information 
 
LYNX must be connected to the telephone line if using Remote Programming. 
The downloading system can perform many functions when in communication with the Control. Besides 
uploading and downloading, the status of the system can be observed and various commands can be 
initiated, as follows: 
•  Arm the system in the away mode; disarm the system. 
•  Bypass a zone. 
•  Force the system to accept a new program download. 
•  Shut down communication (dialer) functions (for nonpayment of monitoring fees in an owned system). 
•  Shut down all security system functions (for nonpayment for a leased system).  
•  Inhibit local keypad programming (prevents account takeover). 
 
 
 