Electrical Connections
IMPORTANT: ENSURE THAT THE ELECTRICITY SUPPLY
IS SWITCHED OFF BEFORE CONNECTING.
17
Your appliance must be connected to fixed wiring via the 
use  of  a  double  pole  switched  fused  spur  outlet  with  at 
least 3mm contact separation.
(See technical data for fuse rating).
We strongly recommend the appliance is connected by a 
qualified  electrician  who  is  a  member  of  the  N.I.C.E.I.C 
who will comply with the I.E.E. and any local regulations.
The terminations labelled SUPPLY are for the connection 
for  the  internal  house  wiring  and  the  terminations 
labelled LOAD are for connection for the appliance.
IMPORTANT
The wires in this mains lead are coloured in accordance 
with the following code:
At  the  colours  of  the  wires  in  the  mains  lead  of  this 
appliance  may  not  correspond  with  the  coloured 
markings  identifying  the  terminals  in  your  spur  box, 
proceed as follows.
The  wire  which  is  coloured  green  and  yellow  must  be 
connected to the terminal which is marked with the letter 
E or by the earth symbol     or coloured green or green 
and  yellow.  The  wire  which  is  coloured  blue  must  be 
connected  to  the  terminal  which  is  marked  with  letter  N 
or  coloured  black.  The  wire  which  is  coloured  brown 
must be connected to the terminal which is marked with 
the letter L or coloured red.
NOTE
The  terminology  "DOUBLE  POLE"  means  that  both 
the  live  and  neutral  supplies  are  switched  and 
disconnected at the same time.
- WARNING -
THIS APPLIANCE MUST BE EARTHED.
TECHNICAL DATA
FUSE RATING:
13AMP
GREEN / YELLOW
BLUE
BROWN
Earth
Neutral
Live
BLUE
(NEUTRAL)
GREEN & YELLOW
(EARTH)
BROWN
(LIVE)