Maxtor SLD240 Benutzerhandbuch

Seite von 77
32 
AUDIO: 
This option determines  the way to record sound if necessary. 
ON: Enables AUDIO recording. 
OFF: Disables AUDIO recording. 
 NOTE: Audio function can only be activated in the following refresh rates: 20, 12, 5.5, 2.4, 
1.22, 0.71 fields/sec 
 
MULTIPLEXER:   
For optimum image recording, please set this option to ON when the DVR  is connected to a 
multiplexer for use. Set this option to OFF when it is only connected to a single camera or Quad 
processor. 
Note: For multiplexer (MUX) setup, refer to Section 4.1.1 
 
 
5.2 ALARM SETTING 
This menu allows users to program the configuration of alarm recording only when an alarm input is 
activated. The device will record as long as the alarm input is activated. 
 
      
ALM OPERATION:   
  This option determines whether to activate/deactivate the alarm recording when it detects an alarm input. 
ON: The device activates the alarm recording when it detects an alarm input. 
OFF: The device ignores the alarm signal when it detects an alarm input. 
 
REC RATE:   
This option is for the purpose of adjusting the number of pictures recorded  per second onto  a  hard disk 
when an alarm input is activated. There are 5 different record speeds you can select from:  60F/S (60 
fields per second), 30F/S, 20F/S, 12F/S, and REMAIN.   If you select REMAIN for use, the device will 
record images at the same speed as set on the REC page. 
 
 
 
MAIN MENU 
 
RECORD 
ALARM  
CLOCK / TIMER 
COMMUNICATION 
DISK 
SYSTEM 
 
 
 
GOTO ALARM PAGE
 
 
     ALARM SETTING 
 
ALM OPERATION      : OFF 
REC RATE 
 
  : 20F/S 
REC QUALITY   
  : BEST 
AUDIO              : OFF 
ALM TYPE 
 
  : NO 
ALM DURATION 
  : 0  SEC 
PRE- ALARM 
 
  : OFF 
MOTION SETTING 
 
 MAIN PAGE 
 
ALARM REC ENABLE