IBM Flex System V7000 Storage Node 4939H49 Benutzerhandbuch

Produktcode
4939H49
Seite von 610
Chapter 1. Introduction to IBM Flex Systems and IBM PureSystems offerings 
17
Draft Document for Review January 29, 2013 12:52 pm
8068ch01-Intro.fm
run at up to 8 GT/s, one integrated memory controller, and four memory channels supporting 
up to three DIMMs each.
The x240 includes 8 GB of memory (2x 4 GB DIMMs) running at either 1600 MHz or 1333 
MHz depending on model. Some models include an Embedded 10Gb Virtual Fabric Ethernet 
LAN-on-motherboard (LOM) controller as standard, this embedded controller precludes the 
use of an I/O adapter in I/O connector 1. Model numbers in the form x2x (for example 
8737-L2x) include an Embedded 10Gb Virtual Fabric Ethernet LAN-on-motherboard (LOM) 
controller as standard. Model numbers in the form x1x (for example 8737-A1x) do not include 
this embedded controller.
The x240 with the Intel Xeon E5-2600 series processors can support up to 768 GB of 
memory in total when using 32 GB LRDIMMs and with both processors installed. The x240 
uses Double Data Rate-3 (DDR-3) low-profile (LP) DIMMs. The x240 supports three types of 
DIMM memory:
��
Registered DIMM (RDIMM) modules
��
Unbuffered DIMM (UDIMM) modules
��
Load-reduced (LRDIMM) modules
The mixing of these different memory DIMM types is not supported.
The x240 compute node features an onboard LSI 2004 SAS controller with two small form 
factor (SFF) hot-swap drive bays that are accessible from the front of the compute node. The 
onboard LSI SAS2004 controller provides RAID 0, RAID 1 or RAID 10 capability and supports 
up to two SFF hot-swap SAS or SATA HDDs or two SFF hot-swap solid state drives. 
Figure 1-8 shows how the LSI2004 SAS controller and hot-swap storage devices connect to 
the internal HDD interface.
Figure 1-8   The LSI2004 SAS controller connections to HDD interface
Each x240 server has an Integrated Management Module version 2 (IMMv2) onboard and 
uses the Unified Extensible Firmware Interface (UEFI) to replace the older BIOS interface.
Embedded 10Gb Virtual Fabric Adapter
Some models of the x240 include an Embedded 10Gb Virtual Fabric Adapter (VFA, also 
known as LAN on Motherboard or LOM) built into the system board. Each of these models 
that includes the embedded 10Gb VFA also has the Compute Node Fabric Connector 
installed in I/O connector 1 (and physically screwed onto the system board) to provide 
connectivity to the Enterprise Chassis midplane.
I/O expansion
The x240 has two PCIe 3.0 x16 I/O expansion connectors for attaching I/O adapter cards. 
There is also another expansion connector designed for future expansion options. The I/O 
expansion connectors are a very high-density 216 pin PCIe connector. By installing I/O 
adapter cards it allows the x240 to connect with switch modules in the IBM Flex System 
Enterprise Chassis.
LSI2004
SAS
Controller
Hot-Swap
Storage
Device 1
Hot-Swap
Storage
Device 2
SAS 0
SAS 1
SAS 0
SAS 1