Applicator Interface Port
1. Refer to
. Turn the printer Off (O) and disconnect the AC
power cord data cable.
2. Refer to
and remove the electronics cover.
3. Refer to
and remove the screws and the blank cover plate (or the
interface board and cables) installed next to the PCMCIA memory card slot. (Save
the screws.)
the screws.)
4. Attach the power cable to J5 on the applicator circuit board, then connect interface
data cable to J4 as needed.
5. Refer to
. Insert the applicator circuit board and cable partially into the
mounting slot. Connect the other end of the interface data cables to one of the open
serial data connectors on the main logic board P30–P36 and the power cable to one
of the open connectors (J5) on the power supply board.
serial data connectors on the main logic board P30–P36 and the power cable to one
of the open connectors (J5) on the power supply board.
6. Slide the applicator circuit board completely into the mounting slot, and secure it
with the screws previously removed.
7. Reinstall the electronics cover.
8. Reinstall the AC power cord and turn the printer On (l).
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it
is highly recommended that the technician wear an antistatic wrist strap
connected to the printer chassis.
is highly recommended that the technician wear an antistatic wrist strap
connected to the printer chassis.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer
from the power source before performing the following maintenance.
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.