Gigamon GigaVUE-TA1 GVS-TA101 Merkblatt
Produktcode
GVS-TA101
Features and Benefits
•
High-density, 640Gb, 1RU low profile design
•
Front to back cooling, hot swap fan and option for
redundant power supply
redundant power supply
•
Aggregation of multiple 10Gb SPAN/TAP traffic
feeds into 10Gb/40Gb uplinks
feeds into 10Gb/40Gb uplinks
•
Support for SFP, SFP+, and QSFP+ media types
Applications
•
Traffic aggregation from multiple low-utilization
10Gb links into 10Gb/40Gb uplinks
10Gb links into 10Gb/40Gb uplinks
•
Monitor multiple 10G and 40G traffic streams from
one central location
one central location
•
Consolidate traffic into 40Gb uplinks into GigaVUE
®
H Series Traffic Visibility Nodes
•
Provide a “Gateway” into the Visibility Fabric
“Gateway to Visibility” Traffic Aggregation Node
GigaVUE-TA1
Product Description
Effective network monitoring and security begins with a properly
constructed Visibility Fabric at 1Gb, 10Gb or 40Gb. Link
aggregation is beneficial to ensure multiple lower utilized segments
are combined into higher utilization Visibility Fabric ports.
constructed Visibility Fabric at 1Gb, 10Gb or 40Gb. Link
aggregation is beneficial to ensure multiple lower utilized segments
are combined into higher utilization Visibility Fabric ports.
Many of the 10Gb links that are running in Enterprise networks are
averaging only 2-5% utilization. The GigaVUE-TA1 Traffic
Aggregation node was designed for networks that have a multitude
of low-utilization 10Gb links and need to aggregate traffic into the
Visibility Fabric. The GigaVUE-TA1 node aggregates many ports of
data together prior to feeding the aggregated traffic into either a
GigaVUE G or H Series product where sophisticated Flow Mapping
filters create a powerful Visibility Fabric.
averaging only 2-5% utilization. The GigaVUE-TA1 Traffic
Aggregation node was designed for networks that have a multitude
of low-utilization 10Gb links and need to aggregate traffic into the
Visibility Fabric. The GigaVUE-TA1 node aggregates many ports of
data together prior to feeding the aggregated traffic into either a
GigaVUE G or H Series product where sophisticated Flow Mapping
filters create a powerful Visibility Fabric.
Multiple 10Gb links can be aggregated into a single 10Gb link if the
utilization is low, or a 40G link for segments with higher utilization.
The low profile 1RU design is intended to be deployed at the top of
rack or end of row in data centers. The system ships standard with
24 x 10Gb SFP+ ports, and can optionally be upgraded by enabling
utilization is low, or a 40G link for segments with higher utilization.
The low profile 1RU design is intended to be deployed at the top of
rack or end of row in data centers. The system ships standard with
24 x 10Gb SFP+ ports, and can optionally be upgraded by enabling
The Smart Route To Visibility
™
a further 24 ports of 10Gb and 4 QSFP+ ports of 40Gb. The system
has hot-swap dual fan-trays as standard, and a single power supply.
A second power supply can be added to provide redundant power
capability. Both AC and DC power is available.
has hot-swap dual fan-trays as standard, and a single power supply.
A second power supply can be added to provide redundant power
capability. Both AC and DC power is available.
Copyright © 2012 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping are registered trademarks of Gigamon, LLC and/or affiliates in the
United States and certain other countries. Visibility Fabric, Traffic Visibility Fabric (TVF), Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks
are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
United States and certain other countries. Visibility Fabric, Traffic Visibility Fabric (TVF), Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks
are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com