UNINTERRUPTIBLE POWER SUPPLY (UPS)
ASK  FOR  LOCAL 
C O N D I T I O N S
YEARS
W
ARRANTY*
MODEL
SLC TWIN RT 0,7 - 3 kVA SLC TWIN RT 4 - 10 kVA
FORMAT
Tower / Rack
TECHNOLOGY  
On-line, double conversion, PFC, double DC bus
INPUT  
Nominal voltage
   208 / 220 / 230 / 240 V
Voltage range
120 ÷ 276 V
 (1)
Frequency
50 / 60 Hz  
Frequency range
±10%  
Power factor
≥0.99
Total Harmonic Distortion (THDi) 
<5%
OUTPUT  
Power factor
0.9
Nominal voltage
   208 / 220 / 230 / 240 V
Voltage accuracy
±1%
Maximum slew rate
1 Hz/s  
Frequency
synchronization
mains present
±10%
free running
±0.2 Hz
±0.1 Hz
Efficiency  
>89% 
(2)
>93%
Total Harmonic Distortion (THDv)
≤2% linear load; ≤5% non-linear load (according to EN 62040-3)
Admissible overload
(normal mode)
Up to 130% during 12 s;
150% during 1.5 s
Up to 125% during 2 min;
150% during 30 s
Crest factor
3 to 1
Paralel
No
Yes, up to 2 units
 BYPASS  
Nominal voltage
   208 / 220 / 230 / 240 V
Admissible frequency range
50 / 60 Hz ±10 Hz  
Independent bypass line
No
Yes
MANUAL BYPASS
No
Yes (‘make before break’ type)
BATTERY  
Type
Sealed lead acid, AGM and free maintenance
Protection 
Against overvoltages, under voltages and alternating current component
CHARGER  
Charge type
 I/U (Constant power/Constant voltage)  
Recharging time
3 hours at 90%  
Compensation voltage for temperature
Yes
COMMUNICATION
Ports  
RS-232 and USB
Monitoring software
For Windows, Unix, Linux and Mac.
Emergency Power Off (E.P.O.)
Yes
FUNCTION MODES
Eco-mode
Yes, up to 98% efficiency
Starting free running (Cold Start)
Yes
Frequency converter
   Yes
 (3)
INDICATORS 
Directable LCD display
GENERALS  
Operating temperature
 0º C ÷ +40º C 
 0º C ÷ +45º C 
Relative humidity
 Up to 95%, non-condensing 
Operating altitude
 1000 m.a.s.l. (degradation power up to 5000 m.a.s.l.)
Acoustic noise @ 1 metre
 <45 dB
 (4)
<55 dB
STANDARDS  
Safety
EN-62040-1; EN-60950-1; EN-60529  
Electromagnetic compatibility (EMC)
EN-62040-2  
Operating
VFI according to EN-62040-3  
Marking
CE  
Quality and environmental 
management
 ISO 9001 and ISO 14001 TÜV  
IEC type AC outputs.
Emergency Power Off (EPO).
USB port.
AC input.
Opto couplers.
SNMP/relays smart slot.
RS-232 interface.
Parallel port.
Maintenance bypass.
Power Factor (PF) = 0.9.
+30% of active power over other UPS with FP = 0.7.
+efficiency (98%) with Eco-mode function.
1.
2.
3.
4.
5.
6.
7.
8.
9.
RS-232 interface.
USB interface.
SNMP/relays smart slot.
Monitoring and management software for 
Windows, Linux, Unix and Mac.
SNMP/web adapter
 (1)
.
AS-400 card
 (1)
.
MODBUS protocol.
 (1)
Temperature-humidity sensor.
 (1)
SLC TWIN RT
RACK/TOWER ON-LINE UPS
700 VA – 10,000 VA
CONNECTIONS
COMMUNICATIONS
HIGHER output power
Data may change without previous notice.
 Model  
Apparent 
power (VA)
Active
power (W)
SLC-700-TWIN RT
700
630
SLC-1000-TWIN RT
1,000
900
SLC-1500-TWIN RT
1,500
1,350
SLC-2000-TWIN RT
2,000
1,800
SLC-3000-TWIN RT
3,000
2,700
SLC-4000-TWIN RT
4,000
3,600
SLC-5000-TWIN RT
5,000
4,500
SLC-6000-TWIN RT
6,000
5,400
SLC-8000-TWIN RT
8,000
7,200
SLC-10000-TWIN RT
10,000
9,000
(1) Optional
TECHNICAL SPECIFICATIONS
MODEL
POWER
(VA / W)
DIMENSIONS
(D x W x H mm.)
WEIGHT
(Kg)
SLC-700-TWIN RT
700 / 630
435 x 438 x 89 (2U)
16
SLC-1000-TWIN RT
1,000 / 900
435 x 438 x 89 (2U)
17
SLC-1500-TWIN RT
1,500 / 1,350
435 x 438 x 89 (2U)
19
SLC-2000-TWIN RT
2,000 / 1,800
435 x 438 x 89 (2U)
20
SLC-3000-TWIN RT
3,000 / 2,700
604 x 438 x 89 (2U)
29
SLC-4000-TWIN RT
4,000 / 3,600
560 x 438 x 133 (3U)
45
SLC-5000-TWIN RT
5,000 / 4,500
560 x 438 x 133 (3U)
46
SLC-6000-TWIN RT
6,000 / 5,400
560 x 438 x 133 (3U)
47
SLC-8000-TWIN RT
8,000 / 7,200
560 x 438 x 223 (5U)
82
SLC-10000-TWIN RT
10,000 / 9,000
560 x 438 x 223 (5U)
83
RANGE
(1) With 50% of load
(2) For units of 700 and 1000 VA >87%
(3) Power reduction of 30%
(4) Models >1500 VA is <50 dB
SLC-6000-TWIN RT
SLC-1500-TWIN RT
Dimensions and weight for standard back-up models
(*) Units ≥ 4 kVA: 1 year 