Enterasys Platinum Distributed Forwarding Engine 7H4382-25 Benutzerhandbuch
Produktcode
7H4382-25
Connecting to the Network
3-16 Installation
Connecting to the Network
on page 3-16 provides the procedures for
connecting unshielded twisted pair (UTP) segments from the network or other devices.
For connections to Mini-GBIC ports on the 7G-6MGBIC, refer to
For connections to Mini-GBIC ports on the 7G-6MGBIC, refer to
Connecting UTP Cables to 7H4382-25
The fixed RJ45 front panel connections of the 7H4382-25 are 10/100 Mbps ports. The ports
have internal crossovers, and also support automatic-polarity sensing when configured
for automatic-negotiation.
have internal crossovers, and also support automatic-polarity sensing when configured
for automatic-negotiation.
If automatic-negotiation is not activated on a port, use a straight-through cable when
connecting a workstation to the port. When connecting a networking device to the port,
such as a bridge, repeater, or router, use a crossover cable.
connecting a workstation to the port. When connecting a networking device to the port,
such as a bridge, repeater, or router, use a crossover cable.
If a port is set for auto-negotiation, automatic-polarity sensing is also activated.
Automatic-polarity sensing eliminates the need for a crossover cable, regardless if the
connection is to another network device or a workstation.
Automatic-polarity sensing eliminates the need for a crossover cable, regardless if the
connection is to another network device or a workstation.
In this procedure, the 7H4382-25 is used as the example to connect a twisted pair segment
to the module. Refer to
to the module. Refer to
1.
Ensure that the device connected to the other end of the segment is powered ON.
2.
Connect the twisted pair segment to the module by inserting the RJ45 connector on
the twisted pair segment into the appropriate RJ45 port connector.
the twisted pair segment into the appropriate RJ45 port connector.
Note: If the DFE-Platinum module is being installed in a network using Link Aggregation,
there are rules concerning the network cable and port configurations that must be followed
for Link Aggregation to operate properly. Before connecting the cables, refer to the Matrix
DFE-Platinum Series Configuration Guide for the configuration information. For details on
how to obtain manuals, refer to the “
there are rules concerning the network cable and port configurations that must be followed
for Link Aggregation to operate properly. Before connecting the cables, refer to the Matrix
DFE-Platinum Series Configuration Guide for the configuration information. For details on
how to obtain manuals, refer to the “
.
Note: All RJ45 front panel ports on the 7H4382-25
support Category 5 Unshielded Twisted
Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3 cable may
be used if the connection is going to be used only for 10 Mbps.
be used if the connection is going to be used only for 10 Mbps.