Avaya Integral 5 Easy BND AR2.X 4999108494 Benutzerhandbuch
Produktcode
4999108494
Installation manual Integral 5 D/E easy
Commissioning
06/07
229
4.999.112.593
Example
Example
The system is configured for 4 lines
and 15 subscribers.
The service technician connects an additional M2A plug-in module with one
line and one subscriber.
The programming mode is activated at a system terminal (menu option or
function *48). The service data input commences (CD **). After the service
password has been entered, the code digit function *0 must be executed.
The identification of all software appears in the display (e.g. ZE5009DE)
After pressing key
or key
, the display shows:
L4 S15 L5 S16
The text L4 S15 is displayed before activation, L5 S16 appears in the
display after the PSW acknowledgement has been received.
If the service technician once again presses key
or key
the
display shows: L5 S16 L5 S16