IBM ServeRAID M5210 SAS/SATA Controller 46C9110 Benutzerhandbuch

Produktcode
46C9110
Seite von 20
ServeRAID M5210 and M5210e SAS/SATA Controllers for IBM System x
6
Support for Integrated MegaRAID (iMR) mode (no cache memory upgrades installed) or MegaRAID 
(MR) mode (requires 1 GB, 2 GB, or 4 GB cache memory upgrade).
iMR mode supports (no cache memory upgrades installed) the following features:
RAID 0, 1, and 10, and, optionally, 5 and 50
Fixed stripe unit size of 64 KB
Self-encrypting drives with optional Zero Cache/RAID 5 upgrade
Both RAID and JBOD (pass-thru mode with system drives) configurations
Up to 16 drives are supported in a RAID configuration.
Up to 63 drives are supported in a JBOD configuration. (JBOD drives can be used as 
bootable drives.)
MR mode supports (1 GB, 2 GB, or 4 GB cache memory upgrade required):
RAID 0, 1, 10, 5, and 50 and, optionally, 6 and 60 (Non-RAID is not supported.)
Configurable stripe unit size from 64 KB up to 1 MB
Self-encrypting drives
Optional SSD performance features (FastPath and CacheCade)
Compliant with Disk Data Format (DDF) configuration on disk (CoD).
S.M.A.R.T. support.
MegaRAID Storage Manager management software.
Feature upgrade matrix
The ServeRAID M5210 and M5210e provide support for RAID 0, 1, and 10 as standard capabilities. 
Additional optional functional upgrades are available to expand the standard capabilities. Some upgrades 
do not depend on other upgrades and can be applied to standard controllers (we call them primary 
upgrades). Certain upgrades cannot be applied to standard controllers and require that other upgrades 
are enabled before applying these upgrades (we call them secondary upgrades). There are two types of 
available upgrades: hardware (HW) and Feature on Demand (FoD). Hardware upgrades contain physical 
parts (for example, cache module or supercapacitor). FoD upgrades are software licenses. The following 
table lists the available primary upgrades, their capabilities, and types.
Table 2. ServeRAID M5210 and M5210e primary upgrades and their features
Feature
RAID 5 and 
50
SED
1 GB
cache
2 GB
cache
4 GB
cache
Flash-
backed
cache
Option description
Part number
Type
Zero Cache/RAID 5 Upgrade
47C8708
FoD
Yes
Yes
No
No
No
No
1GB Cache/RAID 5 Upgrade
47C8656
HW
Yes
Yes
Yes
No
No
No
1GB Flash/RAID 5 Upgrade
47C8660
HW
Yes
Yes
Yes
No
No
Yes
2GB Flash/RAID 5 Upgrade
47C8664
HW
Yes
Yes
No
Yes
No
Yes
4GB Flash/RAID 5 Upgrade
47C8668
HW
Yes
Yes
No
No
Yes
Yes