575 lb (261 kg) @ 0°
262 lb (119 kg) @ 30°
185 lb (84 kg) @ 60°
171 lb (78 kg) @ 90°
44
6.0  Rigging-Strength Ratings and Safety Factors (cont’)
6.41 Working Load Limits for Eyebolts used with VRK Vertical Rigging Kits
Eyebolts are the most convenient way to suspend vertical clusters. Eyebolts attach to the EVF and EVH 
enclosures through the integral M10-1.5 attachment points.  Section 5.21 Anatomy of an EVF or EVH Fly-
ing System Using M10 Eyebolts should be reviewed at this time for more information on eyebolt alignment 
and positioning on the enclosure.  Table 12 shows the WLL per eyebolt with respect to the angle of the 
applied load. Figure 29 shows the suspension-point angles that are referenced in the table. It is a good 
idea to stay within 30° of the maximum WLL of the eyebolt (straight up position) for main suspension lines.
Table 12:
WLL for M10
eyebolts in the
EVI-M10K
eyebolt kit
Figure 29:
Suspension line angle limits for
individual eyebolts, both in plane
of pull (left) and against plane
of pull (right)