Cisco 8-port EFEC Data Muxponder Card 15454-10DME-C= Datenbogen
Produktcode
15454-10DME-C=
Cisco Systems, Inc.
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 10 of 12
Table 6.
DWDM Receive Side Optical Performances
OSNR
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power
Sensitivity
Sensitivity
CD Tolerance
23 dB
OFF
<10E(–12)
–
–8 to –20 dBm C-band
–8 to –19 dBm L-band
±1200 ps/nm
19 dB
OFF
<10E(–12)
–
–8 to –20 dBm C-band
–8 to –19 dBm L-band
±1000 ps/nm
19 dB
OFF
<10E(–12)
–
–8 to –22 dBm C-band
–8 to –21 dBm C-band
–
10 dB
STD
<10E(–5)
<10E(–15)
–8 to –18 dBm
±800 ps/nm
8.5 dB
STD
<10E(–5)
<10E(–15)
–8 to –18 dBm
–
19 dB
ENH
<7x10E(–4)
<10E(–15)
–8 to –26 dBm
±800 ps/nm
14 dB
ENH
<7x10E(–4)
<10E(–15)
–8 to –27 dBm
–
7 dB
ENH
<7x10E(–4)
<10E(–15)
–8 to –18 dBm
±800 ps/nm
5 dB
ENH
<7x10E(–4)
<10E(–15)
–8 to –18 dBm
–
Table 7.
Card Specifications
Specification
Management
Card LEDs
Failure (FAIL)
Active/standby (ACT/STBY)
Signal fail (SF)
Client port LEDS (per port)
Active input signal
DWDM port LEDs
Active input signal
Output wavelength
Red
Green/yellow
Yellow
Green
Green
Green
Power
Card power draw (including SFPs)
Typical
Maximum
40W
50W
Operating environment
Temperature
23 to 131°F (–5 to 55°C)
Humidity
5 to 95 percent noncondensing
Storage environment
Temperature
–40 to 185°F (–40 to 85°C)
Humidity
5 to 95 percent noncondensing