Eaton EBA307-06 Benutzerhandbuch
Hot-swap eNMC module
Eaton’s new hot-swap eNMC (ePDU Network Management
and Control) module can be replaced without the need to
power down your rack. As a result, you not only increase
uptime, but also enhance serviceability and potentially save
$200 to $500 on an unnecessary service call.
and Control) module can be replaced without the need to
power down your rack. As a result, you not only increase
uptime, but also enhance serviceability and potentially save
$200 to $500 on an unnecessary service call.
Advanced LCD pixel display
The new ePDU G3 LCD pixel display simplifies local setup and
trouble shooting. It also allows you to view voltage, power,
total input, meters, LCD orientation and alarm history. In
addition, the menu-driven display changes from blue to amber
during an alarm situation, visually alerting you of a problem.
trouble shooting. It also allows you to view voltage, power,
total input, meters, LCD orientation and alarm history. In
addition, the menu-driven display changes from blue to amber
during an alarm situation, visually alerting you of a problem.
3
EATON Eaton ePDU G3
Color-coded outlet sections
Each color-coded outlet section matches a corresponding
circuit breaker in the new ePDU G3 models. This coding
allows you to easily identify which circuit breaker feeds
which outlets, and prevents unbalanced loading that could
trip a breaker.
circuit breaker in the new ePDU G3 models. This coding
allows you to easily identify which circuit breaker feeds
which outlets, and prevents unbalanced loading that could
trip a breaker.
Hot-swap meter is
able to be replaced
without powering
down the rack.
able to be replaced
without powering
down the rack.
ePDU G3’s advanced LCD pixel display
Local buttons allow for easy menu
navigation and simplify setup
Low-profile form factor
The width of the new ePDU
G3 Basic and Metered Input
ePDUs has been optimized
for side mounting, resulting
in zero interference into
the rail space so you don’t
block hot-swap fans or
power supplies. Some
models feature low-profile
circuit breakers to reduce
interference when the ePDU
is mounted with outlets
facing the rail (center of
the rack).
G3 Basic and Metered Input
ePDUs has been optimized
for side mounting, resulting
in zero interference into
the rail space so you don’t
block hot-swap fans or
power supplies. Some
models feature low-profile
circuit breakers to reduce
interference when the ePDU
is mounted with outlets
facing the rail (center of
the rack).
ePDU G3 in Eaton S-Series rack
ePDU G3 does not interfere
with rail space
with rail space
ePDU G3 mounted at 90-degree angle