MEAN WELL LPF-25D-12 Benutzerhandbuch

Seite von 4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT            
RATED POWER              
OUTPUT
LINE REGULATION      
LOAD REGULATION      
 
SETUP, RISE TIME          
Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE          
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.             
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT             
Note.4
   
OVER VOLTAGE           
 
12V
LPF-25D-12 LPF-25D-15 LPF-25D-20 LPF-25D-24 LPF-25D-30 LPF-25D-36 LPF-25D-42 LPF-25D-48 LPF-25D-54
6.6 ~12V
15V
8.25 ~ 15V
20V
11 ~ 20V
24V
13.2 ~ 24V
30V
16.5 ~ 30V
36V
19.8 ~ 36V
48V
26.4 ~ 48V
2.1A
1.67A
1.25A
1.05A
0.84A
0.7A
0.53A
25.2W
25.05W
25W
25.2W
25.2W
25.2W
25.44W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±4.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
1500ms, 80ms / 115VAC at full load     1500ms, 80ms / 230VAC 
16ms at full load     230VAC /115VAC
90 ~ 305VAC          127 ~ 431VDC
47 ~ 63Hz
84%
84%
85%
85.5%
85.5%
85.5%
86%
COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC
μ
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
418.5Khrs min.      MIL-HDBK-217F (25
)
148*40*32mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 55% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please 
    reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight explosure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.36Kg; 40pcs/ 15.4Kg/1.02CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)  
Note.2
VOLTAGE TOLERANCE  
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION SHORT CIRCUIT             
Hiccup mode, recovers automatically after fault condition is removed.
54V
29.7 ~ 54V
0.47A
25.38W
350mVp-p
±4.0%
±0.5%
±0.5%
42V
23.1 ~ 42V
0.6A
25.2W
250mVp-p
±4.0%
±0.5%
±0.5%
85.5%
86%
15 ~ 18V
17.5 ~ 21V
23 ~ 27V
28 ~ 35V
34 ~ 40V
41 ~ 49V
54 ~ 63V
0.4A / 115VAC          0.25A / 230VAC         0.2A/277VAC
46 ~ 54V
59 ~ 66V
File Name:LPF-25D-SPEC   2013-11-08
25W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
Fully
dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting 
Suitable for dry / damp / wet locations
5 years warranty 
Fully isolated plastic case 
 encapsulated with IP67 level (Note.6)
Class   power unit, no FG
Class 2 power unit
Built-in 3 in 1 
 Features :
L P F - 2 5 D  
s e r i e s
ISOLATION RESISTANCE
CONSTANT CURRENT REGION 
Note.4
SAFETY STANDARDS    
Note.6
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
IP67
F
M
M
110
SELV
OVER TEMPERATURE
EMC IMMUNITY
Compliance to EN55015; EN61000-3-2  Class C (≧55% load) ; EN61000-3-3
EMC EMISSION
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
-35 ~ +70℃ (Refer to "Derating Curve")
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level(surge 2KV),  criteria A
95℃± 5℃(TSW1) Detect on U2
Protection type : Shut down o/p voltage, 
recovers automatically after temperature goes down
UL8750, CSA C22.2 No. 250.0-08,EN61347-1, EN61347-2-13 independent, EN62384,J61347-1,
J61347-2-13 approved, IP67 approved ;Design refer to UL60950-1, TUV EN60950-1