3M 5313 Benutzerhandbuch

Seite von 3
2
Date :   March 1996
5313 Preformed Sealant Strip
Environmental
Characteristics
Ozone Resistance
No Change
Low Temperature
Flexibility (-29°C)
No Cracking
Heat Resistance
(45 minutes at 135°C)
No plasticiser migration, flow, blistering, nor loss of
adhesion.
Test Method
Performance
Ageing Cycle
Tensile
Strength# (PSI,
100% cohesion
failure)
Durometer#
Hardness
(Shore A)
Fatigue
Resistance
*
24 hours at 22°C
336 hours at 88°C
500 hours at 38°C & 95-100% RH
500 hours at 63°C & UV Light
336 hours at 38°C & 95-100% RH
336 hours at 22°C Water Immersion
7
12
9
N/A
N/A
N/A
5
20
15
18
N/A
N/A
N/A
No Failure
N/A
N/A
No Failure
No Failure
# Test performed at 23°C.
*  Bonds deflected 60 mils
horizontally at 665 cycles
per minute at -29°C after
indicated ageing cycle.
("No failure" indicates
100,000 cycles tested
without failure).
Directions for Use
Surface Preparation:
In order to obtain optimum
efficiency, the surfaces
which are to be sealed must
be dry, clean and free from
grease and oil.
Application:
5313 is best applied by
placing it directly on the
surface to be sealed as it is
removed from the roll and
leaving protective liner in
place until ready for final
assembly, this minimises
distortion and dirt pick-up.
Coverage:
Not Applicable
Drying Time:
Not Applicable
Clean Up:
Excess sealer may be
removed by cutting with a
sharp knife or scissors
moistened with water.
Storage Conditions
Store below 22°C for
maximum storage life.