Confirm resources failover
1.
After the iSCSI Software Target resource comes online, expand the Groups list in the left pane.
Right-click Group 0 and select Move Group. Ensure that all Group 0 resources are successfully
moved over to Node 2.
Right-click Group 0 and select Move Group. Ensure that all Group 0 resources are successfully
moved over to Node 2.
2.
Repeat the Move Group operation for Group 1 and the Cluster Group. Verify that all Group 0,
Group 1, and Cluster Group resources have successfully moved over to Node 2 and that Node 2
is now the active node with full control of all cluster resources.
3.
Move Group 0, Group 1, and the Cluster Group back to Node 1. Verify that Node 1 is now the
active node with full control of all cluster resources.
Note
Microsoft recommends shutting down all nodes in the cluster
one at a time and bringing them back online in order to
confirm the successful failover of cluster resources. Moving
the resource groups allows you to test the failover of
resources without completely taking cluster nodes offline.