Add-On Computer Peripherals (ACP) SFP-533-AO Benutzerhandbuch

Seite von 8
www.addoncomputer.com  
Phone:  877.292.1701  
 
3  
not  be  damaged  if  this  contact  is  connected  to  VeeT  or  VeeR  in  the  module.  
The  SFP+  module  provides  two  inputs  RS0  and  RS1  that  can  optionally  be  used  for  rate  selection.  RS0  
controls  the  receive  path  signaling  rate  compatibility,  and  RS1  controls  the  transmit  path  signaling  rate  
compatibility.  The  host  and  module  may  choose  to  use  either,  both,  or  none  of  these  functions.  Because  
contact  9  in  the  classic  SFP  INF-­‐8074i  is  connected  to  VeeR,  and  SFP+  host  utilizing  RS1  must  provide  
short  circuit  protection.  
This  rate  select  functionality  can  also  be  controlled  by  software  as  defined  by  SFF-­‐8472.  Optionally  the  
rate  select  methods  of  Part  2  SFF-­‐8079  may  be  used  instead  of  the  method  described  here  by  setting  the  
management  declaration  bit  (A0h  byte  93  bit  2)  to  1,  see  SFF-­‐8472.  
 
 
Parameter  
State  
Conditions  
RS0  
Low  
Rx  signally  rate  less  than  or  equal  to  4.25GBd.  
High  
Rx  signally  rate  great  than  4.25GBd.  
RS1  
Low  
Tx  signally  rate  less  than  or  equal  to  4.25GBd.  
High  
Tx  signally  rate  great  than  4.25GBd.  
 
 
 
 
 
 
Pin-­‐out  of  connector  Block  on  Host  board