330569-004US 
2.4  Environmental Conditions  
Table 11:  Temperature, Shock, Vibration 
Temperature 
Add-In Card form factor 
2.5-inch form factor 
Temperature 
 
Operating
1
 
 
Non-operating
3
 
 
Ambient 0 – 55
C / 0 -40
C
2
 
-55–95
 
Ambient 0–35
C, Case: 0-70
 o 
Temperature Gradient
 
Operating  
 
Non-operating
 
 
30
C/hr (Typical) 
30
C/hr (Typical) 
 
30
C/hr (Typical) 
30
C/hr (Typical) 
Humidity 
 
Operating 
 
Non-operating
 
 
5–95% 
5–95% 
 
5–95% 
5–95% 
Shock and Vibration 
Range 
Shock
 
Operating 
 
Non-operating
 
 
50 G Trapezoidal, 170 in/s 
50 G Trapezoidal, 170 in/s 
 
1,000 G (Max) at 0.5 msec 
1,000 G (Max) at 0.5 msec 
Vibration
6
 
 
Operating 
 
Non-operating 
 
2.17 GRMS (5-700 Hz) Max 
3.13 GRMS (5-800 Hz) Max 
 
2.17 GRMS (5-700 Hz) Max 
3.13 GRMS (5-800 Hz) Max 
NOTES:  
1. 
Operating temperature implies ambient air temperature under defined airflow in Tables 12 and 13 
2. 
0-55 
o
C is for airflow from the server towards the card and 0-40 
o
C is for airflow into the server 
3. 
Please contact your Intel representative for details on the non-operating temperature range 
4. 
Temperature gradient measured without condensation 
5. 
Shock specifications assume the SSD is mounted securely with the input vibration applied to the  
drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Shock specification is measured using Root Mean 
Squared (RMS) value 
6. 
Vibration specifications assume the SSD is mounted securely with the input vibration applied to the  
drive-mounting screws. Stimulus may be applied in the X, Y or Z axis. Vibration specification is measured using RMS 
value 
Table 12:  Airflow Requirements for Intel SSD DC P3600 Series (Add-In Card) 
Airflow 
Direction 
Unit 
Ambient 
Temperature 
Intel SSD DC P3600 Series 
400GB 
800GB 
1.2TB 
1.6TB  
2TB 
Towards the 
server 
LFM 
40 
o
100 
300 
300 
300 
300 
Out of the 
server 
LFM 
55 
o
100 
300 
300 
300 
300 
NOTE:   For Add-In cards airflow can be for both the directions. Airflow specified is based on approach velocity.