Intel DC P3600 SSDPEDME020T410 Benutzerhandbuch

Produktcode
SSDPEDME020T410
Seite von 43
 
 
Intel
®
 Solid-State Drive DC P3600 Series 
 
Product Specification 
October 2014 
26 
 
 
330569-004US 
Byte 
# of 
Bytes 
Attribute 
Description 
32 
16 
Data Units Read (in LBAs) 
Contains the number of 512 byte data units 
the host has read from the controller; this 
value does not include metadata. This value 
is reported in thousands (i.e., a value of 1 
corresponds to 1000 units of 512 bytes read) 
and is rounded up. When the LBA size is a 
value other than 512 bytes, the controller 
shall convert the amount of data read to 512 
byte units. 
48 
16 
Data Units Write (in LBAs) 
Contains the number of 512 byte data units 
the host has written to the controller; this 
value does not include metadata. This value 
is reported in thousands (i.e., a value of 1 
corresponds to 1000 units of 512 bytes 
written) and is rounded up. When the LBA 
size is a value other than 512 bytes, the 
controller shall convert the amount of data 
written to 512 byte units. For the NVM 
command set, logical blocks written as part of 
Write operations shall be included in this 
value. Write Uncorrectable commands shall 
not impact this value. 
64 
16 
Host Read Commands 
Contains the number of read commands 
issued to the controller. 
80 
16 
Host Write Commands 
Contains the number of write commands 
issued to the controller. 
96 
16 
Controller Busy Time (in minutes) 
Contains the amount of time the controller is 
busy with I/O commands. The controller is 
busy when there is a command outstanding 
to an I/O Queue (specifically, a command was 
issued by way of an I/O Submission Queue 
Tail doorbell write and the corresponding 
completion queue entry has not been posted 
yet to the associated I/O Completion Queue). 
This value is reported in minutes. 
112 
16 
Power Cycles 
Contains the number of power cycles. 
128 
16 
Power On Hours 
Contains the number of power-on hours. This 
does not include time that the controller was 
powered and in a low power state condition. 
144 
16 
Unsafe shutdowns 
Contains the number of unsafe shutdowns. 
This count is incremented when a shutdown 
notification (CC.SHN) is not received prior to 
loss of power. 
160 
16 
Media Errors 
Contains the number of occurrences where 
the controller detected an unrecovered data 
integrity error. Errors such as uncorrectable 
ECC, CRC checksum failure, or LBA tag 
mismatch are included in this field. 
176 
16 
Number of Error Information Log Entries 
Contains the number of Error Information log 
entries over the life of the controller.