LevelOne IEC-1820 IEC1820 Merkblatt

Produktcode
IEC1820
Seite von 2
Order Information
IEC-1820 
10/100 Industrial Media Converter, SC SM 20KM, -40 to 75C IEC61850
Specifications
Package Contents
IEC-1820
Quick Installation Guide
www.level1.com      one world_one brand_one level_
    
MTBF
55.10 years
  
Technology
Standards
 IEEE802.3 10BASE-T, 
  IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x
Forward and 
 Filtering Rate
 14,880pps for 10Mbps
 148,810pps for 100Mbps
Packet Buffer 
Memory
 128K bits
Processing 
 Type
 Store-and-Forward
 Half-duplex back-pressure and IEEE802.3x full-duplex
flow control  
Environment
Operating 
Temperature
 -40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage 
 Temperature
 -40°C  to 85°C  (-40°F to 185°F)
Ambient 
 Relative 
 Humidity
 5% to 95% (non-condensing)
Regulatory Approvals
ISO
 Manufactured in an ISO9001 facility
Safety
 UL508
EMI
 FCC Part 15, Class A
 EN61000-6-4
-  EN55022
-  EN61000-3-2
-  EN61000-3-3
EMS
 IEC61850-3 & IEEE1613: Substation & Power automa-
tion Applications
 EN50121-4: Railway Applications
 EN61000-6-2
-  EN61000-4-2 (ESD Standards)
Contact: + / - 8KV
Air: + / - 15KV
-  EN61000-4-3 (Radiated RFI Standards)
35V/m, 80 to 1000MHz; 80% AM 
-  EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV
D.C. Power Ports: + / - 4KV
-  EN61000-4-5 (Surge Standards)
Signal Ports: + / - 2KV; Line-to-Line
D.C. Power Ports: + / - 2KV; Line-to-earth
-  EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15 - 80MHz; 80% AM 
D.C. Power Ports: 10Vrms @ 0.15 - 80MHz; 80% AM 
-  EN61000-4-8 (Magnetic Field Standards)
1000A/m @ 50, 60Hz
Environmental 
Test 
Compliance
 IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10 - 150Hz, Amplitude 0.35mm (Operation/Storage/
Transport)
 IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
 FED STD 101C Method 5007.1 (Free fall w/ package)
-Tested with Cross Weight and Drop High standard table
Power
Input
 Input Voltage: 12 to 48VDC (Terminal Block) / 
                         12VDC(DC Jack)
Power 
 Consumption
 2.4W MAX. 0.2A @ 12VDC, 0.05A @ 48VDC 
Overload 
Current 
Protection
 Present
Reverse 
Polarity 
Protection
 Present
Mechanical
Casing
 Aluminum case
 IP30
Dimensions
 50mm (W) x 110mm (D) x 135mm (H)
(1.97" (W) x 4.33" (D) x 5.31" (H))
Weight
 0.8Kg (1.76lbs.)
Installation
 DIN-Rail (Top hat type 35mm), Panel, Rack Mounting
Interface
Ethernet Port
 10/100BASE-TX: 1 port
 100BASE-FX: 1 port
LED Indicators
 Per Unit: Power Status (Power 1, Power 2, Fault),
Link-Fault-Pass-Through
 Per Port: 10/100TX: Link/Activity, Full-duplex/Collision,    
Speed 
100FX: Link/Activity, Full-duplex/Collision
Relay Contact
 Relay contact rating with current 1A @ 30VDC,
  0.5A @ 120VAC