APPA 50 & 50II SERIES MULTIMETER
APPA51 APPA52 APPA53II APPA55II
GENERAL:
SPECIFICATIONS:(All at 23°C±5°C, 80% R.H.)
Measurement K-type, -50°C~1300°C, -58°F~1999°F
•
•
N/A
N/A
Range:
K-type, -200°C~-1372°C, -328°F~2501°F
N/A
N/A
•
•
J-type, -210°C~1200°C, -346°F~2192°F
Resolution:
High: 0.1°C or 0.2°F, Low: 1°C or 1°F
•
•
N/A
N/A
0.1°C / 0.1 K / 0.2°F
≤
1000° , 1°C / 1 K / 2°F
≤
1000°
N/A
N/A
•
•
K-type
±(0.3%+1°C) at -50°C~1000°C, ±(0.3%+2°F) at -58°F~1832°F
Accuracy:
±(0.5%+1°C) at 1000~1300°C, ±(0.5%+2°F) at 1832°F~1999°F
±(0.3%+1°C) at -200°C~-100°C, ±(0.3%+2°F) at -328°F~-148°F
±(0.1%+0.7°C) at -99.9°C~999.9°C, ±(0.1%+1.4°F) at-147.8°F~999.9°F
±(0.3%+1°C) at 1000°C~1372°C, ±(0.3%+2°F) at 1000°F~2501°F
J-type
±(0.3%+1.1°C) at -210°C~-100°C, ±(0.3%+2.2°F) at -346°F~-148°F
Accuracy:
±(0.1%+0.8°C) at -99.9°C~999.9°C, ±(0.1%+1.6°F) at-147.8°F~999.9°F
±(0.3%+1°C) at 1000°C~1200°C, ±(0.3%+2°F) at 1000°F~2192°F
Accuracy:
T1-T2
±(0.3% of T1-T2 reading + 2.0°C), ±(0.3% of T1-T2 reading + 4.0°F)
Temperature 0.15(Spec. Acc)/°C, <18°C or>28°C
•
•
Coefficient:
0.1(Spec. Acc)/°C, <18°C or>28°C
N/A
N/A
•
•
Data logging 16,000 records
Capacity:
Computer
Interface
Software:
Input: K-type thermocouple
•
• •(J-type optional) •(J-type optional)
Sampling Rate: 2.5times/sec
•
•
2times/sec 1times/sec
Display: 3
1/2
digit (1999 count) LCD, full annunciators
•
•
N/A
N/A
Triple 4 digit (9999 count) LCD, full annunciators
N/A
N/A
•
•
Overload Indication:
"1" or -"-1" "1"- or -"-1" "----"
"----"
Low Battery Indication:
Selectable Auto Power Off: You can select an APO of OFF, 10, 20, 30, 40, 50 and 60 minutes. N/A
N/A
•
•
Operating Temperature: 0°C~50°C,
≤
80% RH
•
•
•
•
Storage Temperature:
- 20°C ~ 60°C
•
•
•
•
Input Protection: 60V dc or 24Vrms ac maximum
•
•
•
•
Power Requirement: Single 9V battery (NEDA 1604 or IEC 6F22)
•
•
•
•
Battery Life: In hours (Alkaline battery)
250
250
90
90
Size: 64mm(W) x 160mm (L) x 26 mm(H), without holster
•
•
•
•
74mm(W) x 170mm (L) x 39 mm (H), with holster
•
•
•
•
Weight: In grams (with holster)
430
430
430
430
Included with instrument: Type 50BK bead thermocouple, ZnC battery (installed)
Protective holster, belt clip and manual
N/A
N/A
•
•
Optical RS-232 interface cable with Win DTM 50 software
N/A
N/A
•Optional •Optional
Specifictions subject to change without notice.
N/A
N/A
•
•
•
•
N/A
N/A
N/A •(K-type only)
N/A •(Both K and J type)
N/A
N/A
•
•
• •( 50BK X 2PCS ) • •( 50BK X 2PCS )