Bosch RF835E 4.998.121.486 Benutzerhandbuch
![Bosch](https://files.manualsbrain.com/attachments/992db0bc6e4e397e226301d2fb6c3619baa82b37/common/fit/150/50/58e0935709337019a05abb2f9dc9475495d1a6775066eb5a72dc939185f4/brand_logo.png)
Produktcode
4.998.121.486
Certifications and approvals
Australia
RF835 complies with Australian EMC
Europe
RF835E and RF835E-C comply with EN50131‑1,
Grade 2
USA
RF835 complies with Federal Communications
Commission (FCC)
Region
Certification
Australia
RCM
[RF835E only]
Europe
CE
RF835E and RF835E-C models only:
89/336/EEC, EN50082: 1997,
EN50504: 1995, EN55022: 1998
(CISPR 22: 1997 Class B), EN50130-4:
1995, EN61000-3-2: 1995 (-3-3:
1994), EN61000-4-2: 1995 (-4-3:
1996, -4-4: 1995, -4-5: 1995, -4-6:
1996, -4-11: 1994), EN 300 220-3:
2000, EN 300 440-2: 2000, EN 301
489-3
CE
RF835E and RF835E-C models only:
73/23/EEC, IEC 60950: 2000
USA
UL
RF835 only: ANSR: Intrusion Detection
Units (UL639)
Canada
IC
RF835 only: 12491021658
China
CCC
RF835-CHI: 2009031901000562
Brazil
ANATEL
RF835E only: 0255-06-1855
Installation/configuration notes
Compatibility Information
The RF835 Series products are compatible with the
following combinations of receivers and control
panels:
following combinations of receivers and control
panels:
RF835
Receivers
Control Panels
RF3212
Solution Ultima 844, 862, and 880 control panels,
CC488 control panels
RF3213
VR-8 control panels
RF3222
DS7400XiV4 control panels
RF3224
DS7240, DS7220, D6412, D4412
RF835E and RF835E-C
Receivers
Control Panels
RF3212E
Solution Ultima 844, 862, and 880 control
panels, ICP-CC488 control panels
RF3213E
VR-8 control panels
RF3222E
DS7400XiV4 control panels
RF3227E
DS7240, CC7240-A Solution 40 control panel
RF3228E
Marise control panels
RF3249E
DA (Abacus) control panels
Mounting Considerations
• Mounting height for the detector is between 2 m
(6.5 ft) and 2.4 m (8.0 ft).
• The wall tamper cannot be used in corner mount
installations or when using the optional swivel
bracket.
bracket.
• The integral RF transmitter transmits 150 m (500 ft)
in open air. However, in normal operation, it is
recommended that the detector is within 30 m
(100 ft) of the receiver.
recommended that the detector is within 30 m
(100 ft) of the receiver.
Notice
Actual acceptable transmitter range should be
verified for each installation.
Actual acceptable transmitter range should be
verified for each installation.
Battery Recommendations
The following battery types are recommended for
correct operation of your detector: Duracell MN1500
or PC1500, Energizer E91, or Panasonic AM-3.
correct operation of your detector: Duracell MN1500
or PC1500, Energizer E91, or Panasonic AM-3.
Coverage
Top View Broad: 11 m x 11 m (35 ft x 35 ft)
Side View Broad: 11 m x 11 m (35 ft x 35 ft)
Technical specifications
Environmental Considerations
Relative Humidity:
0% to 95% (non-condensing)
Temperature (operating):
0°C to +49°C (+32°F to +120°F)
2 | RF835 Wireless TriTech Detectors