EFB Elektronik 46005.1F Datenbogen

Seite von 1
07.08.13
07.08.13
BT
BT
RoHS
compliant
LSA Disconnection Module 
2/10 10pairs
Art.-No:
46005.1;46005.1F;46005.1R
46005.1x
Mechanical data for plastic insulated copper wire 
•  Conductor diameter: 0.40 to 0.80 mm
•  Outer diameter: 0.68 to 1.60 mm; AWG 26 to 20
Mechanical data for LSA contacts
•  Contact can be connected with 2 conductors (same diameter) 0.50 to 0.65 mm
•  Durability ≥ 50 cycles, with 2 conductors max. 20 cycles
•  Contact material: special brass, silver-plated in contact area ≥ 5 μm
Mechanical data enclosure
•  Material: self-extinguishing polyester PBT
•  Flammability: UL94 V-0
Electrical data
•  Isolation-resistance: > 5 x 104 MΩ
•  Contact resistance: < 1 mΩ
•  AC-Voltage: 2 kV
eff
•  Impulse withstand voltage (wave form 8/20 μs): 3.6 kV
•  Allowed ampacity: 
LSA contact: equivalent to the ampacity of the connected conductor  
LSA connection module - conductor diameter ≥ 0.6 mm: 10 kA
Climatical data
Application in dry or humid rooms without condensation
•  Temperature range: -40°C up to +90°C while storage 
 -20°C up to +80°C while operation
LSA Disconnection Module 2/10 10pairs
Art.-No.
Type
46005.1
without colour code
46005.1F
with colour code
46005.1R
red housing for fire warning applications
•  For LSA backmount frames/channels
•  With large wire routing eyes, printed with numbers 1..0
•  Cable and routing side can be separeted by disconnection plug