Cisco OC-12/STM-4 Pluggable Multi-Mode (500 m) Transceiver Module SFP-OC12-MM= Datenbogen

Produktcode
SFP-OC12-MM=
Seite von 6
 
 
Data Sheet 
© 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 3 of 6 
 
Channelization support for 4 OC-3 or 12 DS-3 or 336 DS-1 or 2000 DS-0 or n x DS-0 
channels, or any combination of these, to a total of 2000 channels 
 
Multilink bundling on T1/E1 channels as per RFC 1990 
 
Subrate DS-3 
 
Bit Error Rate Test (BERT) support on T1/E1 channels  
all 0s, all 1s, 2^11, 2^15, 2^20, 2^20 QRSS, 2^23, alternating 0s and 1s, 1-in-8, 3-in-24, Bit 
error insertion, Framed all zeroes, Framed all ones  
 
BERT support on T3/E3 channels  
T3/E3: 2^23-1 PRBS (inverted), Framed all ones, Framed all zeroes, Bit error insertion, 
2^15, 2^20 
Product Specifications 
Table 1 shows the hardware specifications for the channelized OC-12/STM-4 SPA.  
Table 1. 
Hardware Specifications for the Cisco 2-Port Channelized OC-12 SPA 
Features 
Descriptions 
Product compatibility 
Cisco 10000 Series Routers 
Port density per SPA 
2-port channelized OC-12/STM-4 
Physical interface (channelized 
OC-12) 
OC-12c/STM-4 Small Form-Factor Pluggable (SFP) optics module (refer to optical 
parameters in Table 2) 
Visual status indicators (LEDs): 
  SPA status LED  
  Per-port LEDs  
  Carrier and alarm  
  Active and loopback 
Protocols 
IETF RFC 1490, Frame Relay Encapsulation 
RFC 1662, Point-to-Point Protocol (PPP) in High-Level Data Link Control (HDLC)-like 
framing 
Cisco HDLC 
Multilink PPP (RFC 1990) (as applicable for 2-port channelized OC-12c/STM-4 (DS-1/E1) 
FRF.12, link fragmentation and interleaving (LFI) 
PPP, HDLC, and Frame Relay User Network Interface (UNI) encapsulations 
Features and functions 
DS-3 
  Full- and half-duplex connectivity at DS-3 rate (44.736 MHz)  
  Scrambling and subrate support of major data-service-unit (DSU) vendors  
  C-bit or M23 framing (software selectable)  
  MDL  
  Support for 16- and 32-bit cyclic redundancy check (CRC) (16-bit default)  
  24-hour history maintained for error statistics and failure counts  
  DS-3 alarm and event detection (once-per-second polling)  
  Alarm indication signal (AIS)  
  Out of frame (OOF)  
  Far-end receive failure (FERF)  
DS-1 
  Superframe (SF) and Extended Superframe (ESF) support  
  ANSI T1.403 FDL support  
  Internal or line-derived (loop) clocking, independently selectable on each T1 tributary  
  Error and alarm detection: CRC errors, framing errors, loss of frame (red), AIS (blue), 
remote alarm indication (yellow)  
  Alarm reporting: 24-hour history maintained, 15-minute intervals on all errors  
  BERT at T1 level  
  Loopback capabilities: local, network line and network payload, remote network line, 
and remote network payload at the T1 level