:TRIGger:SLOPe:TUPPer
Syntax
:TRIGger:SLOPe:TUPPer <time>
:TRIGger:SLOPe:TUPPer?
:TRIGger:SLOPe:TUPPer?
Description
Set or query the upper limit of the time in slope trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<time>
Real
16ns to 10s
1μs
Explanation
) is
PGLess and NGLess.
Return
Format
The query returns the upper limit of the time in scientific notation.
Example
:TRIGger:SLOPe:TUPPer 0.000003 /*Set the upper limit of the time to 3μs*/
:TRIGger:SLOPe:TUPPer? /*The query returns 3.000000e-06*/
Related
Command
:TRIGger:SLOPe:TLOWer
Syntax
:TRIGger:SLOPe:TLOWer <time>
:TRIGger:SLOPe:TLOWer?
:TRIGger:SLOPe:TLOWer?
Description
Set or query the lower limit of the time in slope trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<time>
Real
8ns to 9.99s
992ns
Explanation
) is
PGLess and NGLess.
Return
Format
The query returns the lower limit of the time in scientific notation.
Example
:TRIGger:SLOPe:TLOWer 0.000000020 /* Set the lower limit of the time to 20ns*/
:TRIGger:SLOPe:TUPPer? /*The query returns 2.000000e-08*/
Related
Command