  DS2000A User’s Guide 
7-6 
Start Bit
Data Bit
Check Bit
Stop Bit
 
Start Bit: represent when the data starts outputting. Setting the Polarity is 
equivalent to specifying the “Start Bit”. 
Data Bits: represent the number of data bits actually contained in each frame of 
data. 
Check Bit: used to check the correctness of the data transmission. 
  Odd Checkout: the number of “1” in the data bit and check bit is an odd. For 
example, when 0x55 (01010101) is sent, a 1 needs to be filled in the check bit to 
make the number of 1 be an odd.   
  Even Checkout: the number of “1” in the data bit and check bit is an even. For 
example, when 0x55 (01010101) is sent, a 0 should be filled in the check bit. 
  None: there would not be check bit during the transmission. 
 
Press Decode1  Decode to select “RS232” to open the RS232 decoding function 
menu. 
 
1.  TX and RX Channel Setting 
Press TX to select any channel (CH1 or CH2) as the transmitting channel and 
when “OFF” is selected, no transmitting channel is set. Use the same method 
the set the RX channel. What’s more, you need to set the thresholds of the input 
channels of TX and RX. Switch the menu page and press TXThreshold and 
RXThreshold respectively to input the desired threshold values. 
 
2.  Polarity Setting 
Press Polarity to select “Normal” or “Invert” and the default is normal. The 
oscilloscope will select the rising or falling edge as the start position during 
decoding. 
 
3.  Endian Setting 
Press Endian to select “LSB” or “MSB” and the default is “LSB”. 
 
4.  Baud Rate Setting 