12-15  
 
  ON: the waveform editing window only displays the current point.   
  OFF: the waveform editing window displays all the initial points.   
 
 
4.  Current Point 
Press CurPoint and use 
  or the navigation knob to select the point to be 
edited. The range is from 1 to the initial points.   
 
5.  Voltage 
Press Voltage to set the voltage of the current point. The range is from -2.5 V to 
+2.5 V. 
 
6.  Time 
Press Time to set the duration of the current point. This setting is limited by the 
times of the previous point and following point. The time of point 1 is fixed at 0 s.   
 
7.  Insert 
Press Insert to insert a new waveform point between the current point and the 
next point.   
 
8.  Delete 
Press Delete to delete the current point from the waveform and connect the 
remaining points using the current interpolation mode. Note that point 1 can not 
be deleted.   
 
9.  Done 
Press Done to finish editing the current waveform.   
 
10. Save 
Press Save to enter the file store interface. Please refer to the introduction in 
 to save the current waveform file in “.arb” format in the 
internal memory (you can overwrite the original file or save the current 
waveform again).You can select the arbitrary waveforms in the internal or 
external memory for output. For details, refer to the introduction in 
.