DS2000A User’s Guide
 
 
6-9  
 
Advanced Operation 
DS2000A provides advanced operation function that allows users to define operation 
functions. Press MATH  Operate  “Advanced”  Expression  “ON” and the 
editing window as shown in the figure below is displayed. 
 
 
 
Turn    to select any item in “Channel”, “Function”, “Variable”, “Operator” and 
“Figure” (if they are currently available for selection), then press down the knob and 
the item selected will de displayed in the entry box on the right of the “Expression”. 
 
During the expression editing, you can press Delete to delete the character 
currently at the left of the cursor and press Clear to delete all the characters in the 
entry box at any time. 
 
After finishing the expression editing, press Apply and the oscilloscope will operate 
according to the expression you set and display the result. Note that after Apply is 
pressed, the Expression menu will be automatically set to “OFF” but the preset 
expression will still be displayed at the bottom of the screen for your reference. You 
can also press Invert to turn the inverted display of the operation results on or off.   
 
The following are descriptions of the contents in the editing window. 
 
1.  Expression 
Here, it refers to the formulas formed by channel, function, variable, operator 
and figure. The length of the expression is limited to 64 bytes. 
 
2.  Channel 
You can select any channel (CH1 or CH2).