14-12 
Aux Output   
 
Users can set the type of the signal output from the [Trigger Out] connector at the 
rear panel. 
 
Press Utility  AuxOutput to select the desired output type. 
 
1.  TrigOut 
After this type is selected, the oscilloscope outputs a signal that can reflect the 
current capture rate of the oscilloscope at each trigger. Connect this signal to a 
waveform display device, measure the signal frequency and the measurement 
result equals the current acquisition rate.   
 
2.  PassFail 
After this type is selected, the oscilloscope will output a pulse signal when failed 
waveforms are detected. This signal can be connected to other control systems 
to conveniently view the test results. The oscilloscope will output a 3.3 V high 
level when no failed waveform is detected.