Rigol DS1104Z 4-channel oscilloscope, Digital Storage oscilloscope, DS1104Z Benutzerhandbuch

Produktcode
DS1104Z
Seite von 264
 
RIGOL 
DS1000Z User’s Guide
 
 
12-5  
 
To Output Pulse Waveform 
 
Press Src1 Setup to enter the waveform setting interface. Press Wave to select 
“Pulse”, at this point, you can set relative parameter of the sine signal. For the 
specified setting method, please refer to the instruction of 
. “Duty cycle” is introduced only in this chapter. 
 
Duty cycle 
Duty cycle is difined as the percentage that the high level takes up in the whole 
period of pulse. 
 
T
t
Duty Cycle=t/T*100%
 
 
To set the duty cycle 
Press Duty Cycle and use 
  to set the duty cycle of the current pulse signal and 
the range available is from 10% to 90%. 
 
 
To Output DC Waveform 
 
Press Src1 Setup to enter the waveform setting interface. Press Wave to select 
“DC”, at this point, you can output DC signals with -2.5 V to +2.5 V offset. 
 
1.  Output   
Press Output to turn the signal output on or off. 
 
2.  To set DC offset 
Press Offset to set the offset value of the current DC signal and the range 
available is -2.5 V to +2.5 V. For the setting method, please refer to the 
instruction of