PLEASE NOTE THE FOLLOWING:  
 
The CANbus option also provides Measure tools. Measure is a legacy toolset specifically designed for the 
CANbus TDM package. Measurement applications have been improved and made part of the PROTObus 
MAG toolset. However, the CANbus TDM option is handled and covered in a manner differently than 
PROTObus MAG. The difference are explained at the end of this section in PROTObus MAG and CANbus 
TDM Toolset Differences
 (on page 72)
 
Ask your local LeCroy representative for more information about any Serial Data Debug Solution Protocols 
or Toolkits using the Contact LeCroy for Support (on page 199) topic. 
CANbus Decode Setup Detail 
For general information about using controls shown on the main Serial Decode dialog, refer to Accessing The D 
and TD Supported Protocol Toolsets
 (on page 13)
CAN
BUS 
B
ASIC 
R
IGHT
-H
AND 
D
IALOG
 
Access the Serial Decode dialog by touching Analysis → Serial Decode on the menu bar. 
Touch the corresponding Setup... button for your decode. The Decode Setup... along with a corresponding right-
hand dialog is shown. 
CANbus Basic Right-Hand Dialog 
The Basic right-hand dialog provides detailed controls and setup conditions as follows: 
 
 
Viewing - The decode format is displayed here as Hexadecimal for CANbus. 
 
Bitrate - Adjust the bit rate value here to match the bit rate on the bus you are connected to. This bit rate 
selection is dynamically linked to the decoding bit rate (they are always the same value). Use the arrows 
to move through standard bit rates (10, 25, 33.333, 50, 83.333, 100, 125, 250, 500, and 1000 kb/s) and 
make a selection. Or, touch the number twice (with a finger, or using a mouse) and open the pop-up 
keypad to enter the value directly. Any value from 10-1000 kb/s may be entered in this way. 
 
Show Stuff Bits - Mark this checkbox to indicate whether you want stuff bits highlighted on each CAN 
message frame. 
 
Level Type and Level - The message decoding algorithm setup is performed here. The level is normally set 
up in %, and defaults to 50%. To adjust the level, touch inside the number area (highlighting the box title), 
and then use the oscilloscope front panel Adjust knob to adjust. Or touch inside the number area twice 
and select a value using the pop-up numeric keypad. 
The set Level appears as a dotted horizontal line across the oscilloscope grid. 
If your initial decoding indicates that there are a number of error frames, make sure that the level is set to 
a reasonable value.