3.  Yellow LED 
 
ORDER 
Lit
 
CLEARS THE ALARM DISPLAY 
(see § 4.6)
 
STATUS 
OFF 
No alarm detected (all channels) 
Single flash 
There has been an alarm in at least one 
channel at least once 
Double flash 
There is currently an alarm in at least one 
channel 
Rapid flash 
Ready to clear alarm indications 
 
4.  Red LED 
 
ORDER 
Lit
 
ERASES THE MEMORY 
(see § 4.7)
 
STATUS 
OFF 
No data in memory 
Single flash 
Memory partially filled 
Double flash 
Memory full 
Rapid flash 
Ready to erase the memory 
 
5.  Blue LED 
 
ORDER 
Lit 
STOPS THE DEVICE 
STATUS 
OFF 
Battery voltage OK (> 2.2 volts) 
Single flash 
Batteries worn, must be replaced (< 2.2 
volts) 
Double flash 
Confirms the programming of a recording 
 
* To determine whether the device is off or in standby mode, press the "PRESS" button for 0.5 second: if all 
of the LEDs light, the device is not off. 
 
 
 
Note:  The overload warning appears as soon as an input quantity exceeds by 10% the 
specified value of the input range. 
When the battery voltage falls below 1.7 volt, the device stops automatically (if a recording is in progress, it is 
stopped and the data are saved). 
 
 
Sleep mode: The device switches to low-consumption mode after one minute with no press of the button 
and remains in this mode for as long as the button is not pressed or until the time at which programmed 
recording is to be started is reached. 
 
Recording mode: 
The device switches to low-consumption mode between measurement acquisition stages. 
The lower the recording frequency, the larger the fraction of the time spent in low-consumption mode, and so 
the longer the possible total recording time. 
 
OFF mode: 
The device is in low-consumption mode; it will switch on automatically to start programmed 
recording.