Megger VDE-tester 1005-019 Datenbogen
Produktcode
1005-019
PAT400 SERIES
Portable Appliance Testers
SPECIFICATIONS
Electrical supply range
PAT410 and PAT450
PAT410 and PAT450
230 V ± 10% @ 50/60 Hz
Bond test (10 A and 25 A) (not PAT410)
Open circuit voltage:
Open circuit voltage:
9 V a.c. ± 10% ± 0.1 V
(Supply:
230
V
50Hz)
Earth bond resistance accuracy:
±5% ±3 digits (0 to 0.49 Ω)
±5% ±5 digits 0.5 to .99 Ω)
Earth bond resistance resolution: 10 mΩ (0 to 1.99 Ω)
Display range:
Display range:
0 to 1.99 Ω
Continuity test (200 mA)
Continuity test voltage:
Continuity test voltage:
4.0 V d.c. -0% +10%
Continuity resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω)
±5% ±5 digits 0.5 to .99 Ω)
Continuity resistance resolution: 10 mΩ (1 to 19.99 Ω)
Display range:
Display range:
0 to 19.99 Ω
Insulation test (250 V and 500 V)
Insulation resistance accuracy (230 V):
Insulation resistance accuracy (230 V):
±2% ±5 digits (0 to 19.99 MΩ)
±5% ±10 digits (20 to 99.99 MΩ)
Insulation resistance resolution: 0.01 MΩ
Display range:
Display range:
0 to 99.99 MΩ
Substitute leakage test
Test voltage and frequency:
Test voltage and frequency:
40 V a.c. ±10% nominal mains
frequency
Leakage current accuracy:
Leakage current accuracy:
±5% ±5 digits
Leakage current resolution:
0.01 mA
Display range:
0 to 19.99 mA
Differential leakage current
Test voltage and frequency:
Test voltage and frequency:
Nominal mains supply
Differential leakage current accuracy: ±5% ±5 digits
Differential leakage current resolution: 0.01 mA
Display range:
Differential leakage current resolution: 0.01 mA
Display range:
0 to 19.99 mA
Touch current test
Test voltage and frequency:
Test voltage and frequency:
Nominal mains supply
Touch current accuracy:
±5% ±5 digits
Touch current resolution:
0.01 mA
Display:
0 to 10 mA
Operational test
Test voltage and frequency:
Test voltage and frequency:
Nominal mains supply
VA accuracy:
±5% ±10 digits (0 - 99 VA)
±5% ±50 digits (100 VA - 999 VA)
±5% ±100 digits (1000 VA - 3700 VA)
Resolution:
1 VA (0 to 3700 VA)
Display range:
0 to 3999 VA
Extension lead test
Tests performed:
Tests performed:
Bond, insulation and polarity
Polarity test voltage:
12 V
Polarity checks:
Lead OK
Live
neutral
S/C
Live
neutral
reversed
Live/neutral
O/C
PAT410 PAT450
SUPPLY
230 V
230 V
n
n
Supply measurement
n
n
EARTH BOND/CONTINUITY
200 mA
200 mA
n
n
10 A
n
25 A
n
Bond lead null
n
n
INSULATION TEST
250 V
n
n
500 V
n
n
ALTERNATIVE LEAKAGE TESTS
Substitute
n
n
Differential
n
n
Touch current
n
n
OPERATION TEST
VA Measurement
n
n
EXTENSION LEAD TESTS
Earth bond
Earth bond
n
n
Insulation
n
n
Polarity
n
n
Portable RCD tests
n
n
FLASH TEST
1.5 kV and 3 kV
1.5 kV and 3 kV
n
OTHER FEATURES
Low-profile light weight
n
Auto test routine
n
n
Manual testing
n
n
Fuse check
n
n
Colour display
n
n
Configurable tests times
n
n
Selectable pass limits
n
n
Lead storage pouch
n
n
10,000 record on-board storage
n
n
Download to USB memory stick
n
n
PowerSuite compatible
n
n