Gmw TG UNI 1VDE-tester DIN VDE 0701/ 0702 61000 00100 Benutzerhandbuch
Produktcode
61000 00100
5. Operating elements
Explanation of the tetster’s connections, operating elements and displays
Explanation of the tetster’s connections, operating elements and displays
Mains cable with mains plug
for connecting the Tester to
the mains power supply
230 V +/-15%, 50 Hz
for connecting the Tester to
the mains power supply
230 V +/-15%, 50 Hz
Thermal fuse for the test
object and tetster F 16 A
object and tetster F 16 A
ON / OFF switch
Card slot for an MMC memory
card
card
USB socket for connecting a
PC
PC
RS232 socket for
connecting a barcode
scanner
connecting a barcode
scanner
Touch-screen (LC display and control screen)
Test / mains socket for connecting the test object with earted
plug , 230 V 16 A, 50 Hz
plug , 230 V 16 A, 50 Hz
Connecting socket ‘PE’ (yellow/green), parallel
connection of the protective conductor of the
test socket, for connecting the test object
without an earthed mains plug
connection of the protective conductor of the
test socket, for connecting the test object
without an earthed mains plug
Front panel, Fig. 1
connecting socket ´Probe´ (red), for the test line
when measuring R
when measuring R
PE
and R
INS
Optional connecting sockets (VDE 0751):
´L1´ (black)
´N´ (blue)
´I
´L1´ (black)
´N´ (blue)
´I
EPA
´ (red)
5.1 Meaning of the signal tones
–
short single tone:
confirmation of button press
–
short double tone:
end of a test stage with automatic
procedure
–
long single tone,
continuous tone:
continuous tone:
fault
Storage compartment for the
mains cable
mains cable
8
Operating manual for the TG uni 1 appliance tester
Operating elements
Operating elements
Case housing
Fig. 2
Fig. 2
Housing cover with 2 snap fasteners
Accessories bag with quick guide
Handle (fold-away)
Symbols used in the LC display:
- internal memory
- MMC memory card