Set ® Dual battery charger ZWEITBATTERIE LADER Equalizer EQ24 2424624 Merkblatt
Produktcode
2424624
Kiscsikós köz 10 Budapest 1033 Hungary, tel: +36-1-368-6212 fax:+36-1-250-1168
E mail : forex@forex.hu Internet : www.forex.hu
E mail : forex@forex.hu Internet : www.forex.hu
Charging Equaliser
The problem is evergreen.
Two 12 V batteries connected in serial can never be charged equally. One of
them accepts lower (e.g. 13.6 V), the other higher (15.2 V) charging voltage at
the same charging current.
Two 12 V batteries connected in serial can never be charged equally. One of
them accepts lower (e.g. 13.6 V), the other higher (15.2 V) charging voltage at
the same charging current.
This imbalance is self progressive and shortens the life of both batteries, due to
sulphating (caused by undercharging) and drying up (caused by overcharging)
sulphating (caused by undercharging) and drying up (caused by overcharging)
Section 1 Section 2 Section 3 Section4
To demonstrate the effect of our equalizer we connected
two new batteries in serial and measured the voltages at
their terminals, when:
Section 1: They were not connected to charger and
EQUALIZER. (OCV:
12.72V
and
12.71V
)
Section 2 : They were connected to 28.8 V constant voltage
charger without EQUALIZER (
charger without EQUALIZER (
13.6V
and
15.2V
)
Section 3: They were connected to charger and
EQUALIZER. (
EQUALIZER. (
14.38 V
and
14.42 V
)
Section 4: They were connected to charger without
EQUALIZER again. (
EQUALIZER again. (
13.6 V
and
15.2 V
)
It can be seen, that the Charging Equaliser immediately eliminates the charging voltage imbalance
, and guaranties the equal charging voltage which results equal state of charge of the batteries.
, and guaranties the equal charging voltage which results equal state of charge of the batteries.
Results:
-
decreasing voltage on the overcharged battery
-
increasing voltage on the undercharged battery
-
increased starting current because of equal state of charge
-
increased battery life
Application:
trucks, buses
wheel chairs, cleaning machines
anywhere where 12 V batteries are connected in series
wheel chairs, cleaning machines
anywhere where 12 V batteries are connected in series
Changing of voltages
measured on two series connected batteries while charged with constant 28,8V
(Maxxima 900 and Maxxima 900DC)
13
13,5
14
14,5
15
15,5
16
0
5
10
15
20
25
30
35
40
45
50
55
60
t(h)
U(V)
Maxxima 900
Maxxima 900 DC
12,5
13,0
13,5
14,0
14,5
15,0
15,5
0
30
60
90
120
150
180
210
240
270
300
[minute]
U[V]
1st Battery
2nd Battery
14,4V
2nd Battery
14,4V