IVT Automatic charger Automatik-Ladegerät 12 V 10 A PL-C010P 911008 Benutzerhandbuch

Produktcode
911008
Seite von 24
 
- 8 - 
DESCRIPTION OF LED / OVERVIEW OF FUNCTIONS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LED 
Symbol 
Description 
 
Charging status indicator  
 
Charging status indicator 
 
Charging status indicator 
 
Charging status indicator 
 
Indicator for summer mode  
This LED lights up when the summer mode for lead and calcium batteries is activated. 
 
Indicator for winter mode 
This LED lights up when the winter mode for lead and calcium batteries is activated. 
Maintenance 
Indicator for maintenance mode (Maintenance charge. Only for lead batteries!) 
 
MODE button  
This button is used to select between summer, winter and maintenance mode. 
 
POWER 
Operating status indicator (Mains voltage is applied.) 
10 
 
Indicator for short circuit  
11 
 
Indicator for incorrectly connected 
12 
 
Indicator for defect rechargeable battery 
13 
Lead 
Indicator for lead mode 
This LED lights up when a mode for charging lead batteries is selected. 
14 
Lead Boost 
Indicator for boost mode 
This LED lights up when the boost mode (only for lead batteries) is activated. 
15 
Calcium 
Indicator for calcium mode 
This LED lights up when a mode for charging calcium batteries is selected. 
16 
Power Supply 
Indicator for power supply function 
This LED lights up when the power supply function is selected. 
17 
 
SET button 
This button is used to select between lead, boost, calcium mode or power supply function. 
 
 
CHARGING A LEAD BATTERY 
•  First ensure that it is a lead-acid battery with a voltage of 12 V.  
Caution! Rechargeable batteries with other voltages cannot be charged! 
•  Disconnect all consumers from the rechargeable battery. 
•  If the rechargeable battery is built into a vehicle, switch off the ignition and all consumers. 
 
 
Please strictly observe information and safety notes of the car manufacturer concerning the charging of the rechargeable car battery. 
Modern cars are equipped with sensitive electronic components and control units which will be damaged when handled improperly! 
 
•  First, connect the charger to a mains socket (220 – 240 VAC/50/60 Hz).  
•  First, select the desired function (lead, boost, calcium or power supply) using the 'SET' button. 
•  Now, connect the charger to the rechargeable battery observing correct polarity. For this purpose use the appropriate connection adapter (with battery terminals, 
with rings or with 12 V plugs).