Panasonic HE2AN24 PCB Mount Relay 24V 2 NO, DPST-NO HE2AN24 Datenbogen

Produktcode
HE2AN24
Seite von 6
HE
6
ds_61120_0000_en_he: 061006J
DIMENSIONS
mm 
inch
MOUNTING METHOD
NOTE
HE RELAY ACCESSORIES
Terminal socket instantly attachable to DIN rail
TYPES
SPECIFICATIONS
* Don’t insert or remove relays while in the energized condition.
Part No.
Applicable relays
JH1-SF
HE1a
JH2-SF
HE2a
Part No.
JH1, JH2
Maximum continuous 
current*
20 A 250 V AC (1a: 30 A 250 V AC)
Breakdown voltage
2,000 Vrms between terminals
Insulation resistance
More than 1,000 M
Ω between poles
Heat resistance
150
°C ±3°C for 1 hour
1 Form A, 2 Form A
60
2.362
22
.866
11
.433
9.2
.362
14.4
.567
16
.630
23
.906
11
.433
8.4
.331
34
1.339
70
2.756
4
.157
10.25
.404
9
.354
9
.354
6
8
7
5
1
2
3
4
Relay mounting diagram
Panel cutout
61
2.402
40
1.575
2-DIA. 4.2
2-DIA. .165
(2-M4 Screw hole)
(2-M.157 Screw hole)
Note:
JH1-SF does not have receptacles (tooth rests) for numbers 2, 3, 7, and 8. 
JH2-SF does not have receptacles (tooth rests) for numbers 7 and 8.
1. Relay mounting
2. Installing to a DIN rail
3. Removing from a DIN rail
Push
Flat-head screw driver
1. Be careful not to drop the relay. It is 
made of heat-hardened resin and may 
break.
2. Be sure to tighten the screw-down 
terminals firmly. Loose terminals may 
lead to the generation of heat.