APPLICATION NOTES
If required a breathing hole can be made in the cover by removing the nipple.
However be aware that the degree of protection will reduce from IP67 to IP30!
Operation of forcibly guided contacts, Type B
If an outer contact should weld, then the forced operated inner contacts driven by the actuator remain open.
The rotating armature remains free to move. 
The unaffected contact pairs can operate normally, i.e. their function to make or break remains unaffected.
If an inner contact should weld, then the movement of the rotating armature is blocked via the actuator. 
Open contacts of all four contact pairs remain open. 
This arrangement corresponds to a conventional forcibly guided contact operation.
For Cautions for Use, see 
Connection diagram and pcb 
bore hole data
Contact current characteristics
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
13
5
14
18
19
11
12
20
8
16
15
7
6
-
2
1
+
9
17
10
Grid 2.54
2.73
7.6
1.4 - typical value for manual insertion
1.6 - typical value for automatic insertion
5.68
Bottom view
The contacts are shown in the deenergized condition.
-50 -40 -30 -20 -10
0
10 20
80
70
60
50
40
30
100
90
110
5
10
25
20
15
Ucoil = 0%, 
Load on NC 5 -6
Ucoil = 100%,  Load on NO 7 - 8
Ucoil = 100%,  Load on all 4 NO
The curves are determined by
the contact resistance
Ambient temperature [°C]
Thermal continuous current  I th [A]
Actuator
Nipple
Outer contact
Inner contact
Rotating armature
Actuator
Outer contact
Inner contact
Rotating armature
Actuator
Outer contact
Inner contact
Rotating armature