TE Connectivity 6-1393091-8 MT321012 10A Multimode Relay 3 changeover contacts 12 Vdc 6-1393091-8 Datenbogen
Produktcode
6-1393091-8
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
1
Multimode Relay MT
I
2 / 3 pole 10 A, 2 CO or 3 CO contacts
I
DC and AC coils
I
Mechanical indicator as standard
I
Electrical indicator
I
New test system with front operated finger protected
push-to-test button and integral locking test tab
push-to-test button and integral locking test tab
I
White write on panel
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0415
as per product date code 0415
Applications
Mechanical engineering, plant control
F0161-A
Approvals
V
REG.-Nr. 6182,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
2 CO or 3 CO
Contact set
single cont.
single cont.
bifurcated
Type of interruption
micro disconnection
Rated current
10 A
10 A
4 A
Rated voltage / max.switching voltage AC
240/400 VAC
Maximum breaking capacity AC
2500 VA
2500 VA
500 VA
Limiting making capacity, max 20 ms
20 A
20 A
8 A
Contact material
AgNi90/10
AgNi90/10
AgNi90/10
gold plated
gold plated
Minimum contact load
12V/10mA
20mV/1mA
20mV/1mA
Mechanical endurance
20x10
6
cycles
Rated frequency of operation with / without load
20/100 min
-1
Contact ratings
Type
Type
Load
Cycles
MT321
10 A, 250 VAC, CO contact, cos
ϕ=1, 360/h, df 50%, 35°C
2.2x10
5
MT321
I
on
50 A, I
off
5 A, 3x440 VAC, NO, cos
ϕ=0.3, AC15, normal cond.
6x10
3
MT321
I
on
30 A, I
off
3 A, 3x440 VAC, NC, cos
ϕ=0.3, AC15, normal cond.
6x10
3
MT3..
2 A, 125 V, L/R 30 ms, 3 NO contacts in series, 1800/h, DF 10%
1x10
5
MT2..
0.7 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10%
2x10
5
MT2..
1 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10%
4x10
4
Coil data
Rated coil voltage range DC coil
6...220 VDC
AC coil
6...230 VAC
Coil power DC coil
1.2 W
AC coil
2.3 VA
Operative range
1
Coil versions, DC-coil
Coil code
Coil code
Rated
Operate
Release
Coil
Rated coil
STD
PD*)
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
W
006
0A6
6
4.5
0.6
32+10%
1.1
012
0B2
12
9.0
1.2
110+10%
1.3
024
0C4
24
18.0
2.4
475+
+10%
1.2
048
0E8
48
36.0
4.8
2000+10%
1.2
060
0G0
60
45.0
6.0
2850+10%
1.3
110
1B0
110
82.5
11.5
10000+12%
1.2
220
2C0
220
165.0
22.0
40000+15%
1.2
All figures are given for coil without preenergization, at ambient temperature +23°C
*) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10