Panasonic TX212 Print PCB Mount Relay 12V 2 CO, DPDT TX212 Print Datenbogen
Produktcode
TX212 Print
TX
1
ds_61022_0000_en_tx: 071206J
SPECIFICATIONS
2 A CAPACITY RELAY
WITH HIGH SURGE
VOLTAGE & HIGH
BREAKDOWN VOLTAGE
TX RELAYS
TESTING
mm
inch
8.2
.323
7.4
.291
15
.591
8.4
.331
7.4
.291
15
.591
FEATURES
• Breakdown voltage between contacts and coil: 2,000 V
• Surge withstand between contacts and coil: 2,500 V
• High contact capacity: 2 A 30 V DC
• Surface-mount type available
Contact
Notes:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type or SX relays are available for low level load
switching [10V DC, 10mA max. level])
actual load. (AgPd contact type or SX relays are available for low level load
switching [10V DC, 10mA max. level])
#2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C
temperature range is from –40 to +70°C
–40° to +158°F
.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current:
2 A.
2 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10
μs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10
μs.
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
.
Characteristics
Arrangement
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material
Standard contact:
Ag+Au clad, AgPd contact
(low level load):
AgPd+Au clad (stationary),
AgPd (movable)
Rating
Nominal switching capacity
(resistive load)
(resistive load)
2 A 30 V DC
Max. switching power
(resistive load)
(resistive load)
60 W
Max. switching voltage
220 V DC
Max. switching current
2 A
Min. switching capacity
(Reference value)
(Reference value)
#1
10
μA 10 mV DC
Nominal
operating
power
operating
power
Single side stable
140 mW (1.5 to 24 V DC)
270 mW (48 V DC)
1 coil latching
100 mW (1.5 to 24 V DC)
2 coil latching
200 mW (1.5 to 24 V DC)
Expected
life (min.
operations)
life (min.
operations)
Mechanical (at 180 cpm)
10
8
Electrical
(at 20 cpm)
(at 20 cpm)
2 A 30 V DC
resistive
resistive
10
5
1 A 30 V DC
resistive
resistive
5
×10
5
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial
breakdown
voltage
breakdown
voltage
Between open
contacts
contacts
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and
coil
coil
2,000 Vrms for 1 min.
(Detection current: 10 mA)
Initial surge
voltage
voltage
Between open
contacts
(10
contacts
(10
×160 μs)
1,500 V (FCC Part 68)
Between contacts and
coil (2
coil (2
×10 μs)
2,500 V (Telcordia)
Temperature rise*
2
(at 20
°C)
Max. 50
°C
Operate time [Set time]*
3
(at 20
°C)
Max. 4 ms [Max. 4 ms]
Release time [Reset time]*
4
(at 20
°C)
Max. 4 ms [Max. 4 ms]
Shock resistance
Functional*
5
Min. 750 m/s
2
{75 G}
Destructive*
6
Min. 1,000 m/s
2
{100 G}
Vibration resistance
Functional*
7
196 m/s
2
{20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
Destructive
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for
operation, transport
and storage*
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
condensing at low
temperature)
Ambient
temperature
temperature
#2
–40
°C to +85°C (up to 24 V coil)
–40
°F to +185°F
(up to 24 V coil)
–40
°C to +70°C (48 V coil)
–40
°F to +158°F
(48 V coil)
Humidity
5 to 85% R.H.
Unit weight
Approx. 2 g .
071 oz