Panasonic S412 PCB Mount Relay 12V 4 NO, 4PST S412 Datenbogen

Produktcode
S412
Seite von 5
S
5
ds_61105_0000_en_s: 151106D
NOTES
CAUTIONS FOR USE
For Cautions for Use, see 
1. Special use of 2 coil latching types: 2 
ways can be considered if 2 coil latching 
types are used as 1 coil latching types.
(A) Reverse polarity is applied to the set 
coil of 2 coil latching type.
(B) By shorting terminals 12 and 7, apply 
plus to 1, minus to 6 at set and plus to 6, 
minus to 1 at reset. Applied coil voltage 
should be the same as the nominal. 
Operating power will be reduced to one-
half.
Reset position of 2a2b type
2. Soldering operations should be 
accomplished as quick as possible; 
within 10 seconds at 250
°C 
482
°F
 solder 
temperature or 3 seconds at 350
°C 
662
°F
. The header portion being sealed 
with epoxy resin, undue subjection to 
heat may cause loss of seal. Solder 
should not be permitted to remain on the 
header.
1
2
3
4
5
6
12
11
10
9
8
7
-
+
Based on regulations regarding insulation distance, there is a 
restriction on same-channel load connections between terminals 
No. 2, 3 and 4, 5, as well as between No. 8, 9 and 10, 11. See 
the figure below for an example.
4
2
5
3
10
9
4
8
11
5
2 3
9
8
11
O
 Between 2, 3 and 4, 5:
O
 Between 10, 11 and 8, 9:
same channels, therefore possible
same channels, therefore possible
O
 Between 2, 3 and 4, 5:
O
 Between 10, 11 and 8, 9:
different channels, therefore not possible
different channels, therefore not possible
10
No good
Good