Panasonic HY1Z-24 V PCB Mount Relay 24Vdc 1 CO, SPDT HY1Z-24 V Datenbogen

Produktcode
HY1Z-24 V
Seite von 4
HY
1
ds_61012_0000_en_hy: 061006J
SPECIFICATIONS
TYPICAL APPLICATIONS
NON-POLARIZED 
1 FORM C RELAY
HY RELAYS
7.4
.291
10.1
.398
  12
.472
mm 
inch
FEATURES
• High sensitivity: 150 mW/200 mW
• A wide range of ambient temperature: –40
°C to +70°
–40
°F to +158°F
• Sealed construction
• Rating: 1 A 30 V DC
Contact
Coil
Note:
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
μs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
μs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in 
Characteristics (at 25
°
77
°F
, 50% Relative humidity)
Arrangement
1 Form C
Initial contact resistance, max. 
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material
Gold-clad silver
Rating 
(resistive)
Nominal switching capacity
1 A 30 V DC
Max. switching power
30 W
Max. switching voltage
60 V DC
Max. switching current
1 A
Max. carrying current
2 A
Min. switching capacity 
(Reference value)
#1
1 mA, 1 V DC
Expected life 
(min. operations)
Mechanical (at 180 cpm)
10
7
Electrical (at 20 cpm) 
1 A 30 V DC
10
5
Nominal operating 
power
Standard type
200 mW
High sensitivity type
150 mW
Max. operating speed
20 cpm (at nominal voltage)
Initial 
insulation 
resistance*
1
Between contacts
Min. 100 M
Ω at 500 V DC
Between contact and 
coil
Min. 100 M
Ω at 500 V DC
Initial 
breakdown 
voltage*
2
Between open 
contacts
500 Vrms
Between contacts and 
coil
1,000 Vrms
Operate time*
3
 (at nominal voltage)
Max. 5 ms
Release time (without diode)*
3
(at nominal voltage)
Max. 4 ms
Temperature rise at nominal voltage 
Contact carrying current 1 A at 20
°C
Max. 50
°C
Shock resistance
Functional*
4
Min. 98 m/s
2
 (10 G)
Destructive*
5
Min. 980 m/s
2
 (100 G)
Vibration resistance
Functional*
6
58.8 m/s
2
 {6 G}, 10 to 55 Hz 
at double amplitude of 1 mm
Destructive
117.6 m/s
2
 {12 G}, 10 to 55 Hz 
at double amplitude of 2 mm
Conditions for 
operation, transport 
and storage*
7
 
(Not freezing and 
condensing at low 
temperature)
Ambient 
temp.
–40
°C to +70°C 
–40
°F to +158°F
Humidity
5 to 85% R.H.
Unit weight
1.8 g 
.063 oz
• Automotive: Switching to small motor
1) Automirrow controller
2)Retractable head light controller
• Push button device: Dial pulsing
• Low-voltage signal switching and motor 
control of small home appliances such 
as portable video tape recorders and 
audio devices.
• Operating of dish-control motors for 
PCs and word processors