Panasonic ALDP112 PCB Mount Relay 1 NO, SPST-NO ALDP112 Datenbogen

Produktcode
ALDP112
Seite von 4
LD-P (ALDP)
4
ds_61B10_0004_en_ldp: 021009D
NOTES
For Cautions for Use, see 
Q Usage, transport and storage 
conditions
1) Temperature: 
–40 to +85
°C 
–40 to +185
°F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the 
temperature. Use within the range 
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for 
usage, transport, and storage
4) Condensation
Condensation forms when there is a 
sudden change in temperature under 
high temperature and high humidity 
conditions. Condensation will cause 
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may 
freeze on the relay when the 
temperatures is lower than 0
°C 
32
°F
This causes problems such as sticking of 
movable parts or operational time lags.
6) Low temperature, low humidity 
environments
The plastic becomes brittle if the relay is 
exposed to a low temperature, low 
humidity environment for long periods of 
time.
Q Solder and cleaning conditions
1) Please obey the following conditions 
when soldering automatically.
(1) Preheating: Within 120
°C 
248
°F
 
(solder surface terminal portion) and 
within 120 seconds
(2) Soldering iron: 260
°C±5°C 
500
°F±41°F
 (solder temperature) and 
within 6 seconds (soldering time)
2) Do not use ultrasonic cleaning.
This will adversely affect the relay 
characteristics. Also, it is recommended 
that alcoholic solvents be used.
Q Certification
1) This relay is UL and C-UL certified.
UL and C-UL standards:
    5 A 277 V AC 70
°C
    5 A 30 V DC
2) This relay is certified by VDE.
VDE standards:
    5 A 250 V AC cos
φ
 = 1.0  70
°C
    5 A 30 V DC 0ms
3) UL, C-UL and VDE certified ratings are 
displayed on the packaging box.
(On the relay, only the certification marks 
are shown and not the certified ratings. 
Please refer to the product specification 
diagrams to see what is stamped.)
Q Part number display
The “W” at the end of the part number 
only appears on the inner and outer 
packaging. It does not appear on the 
relay itself.
Q Others
1) To ensure good operation, please keep 
the voltage on the coil ends to 
±5% (at 
20
°C 
68
°F
) of the rated coil operation 
voltage. Also, please be aware that the 
pick-up voltage and drop-out voltage may 
change depending on the temperature 
and conditions of use.
2) Keep the ripple rate of the nominal coil 
voltage below 5%.
3) The cycle lifetime is defined under the 
standard test condition specified in the 
JIS C 5442 standard (temperature 15 to 
35
°C 
59 to 95
°F
, humidity 25 to 
75%R.H.). Check this with the real device 
as it is affected by coil driving circuit, load 
type, activation frequency, activation 
phase, ambient conditions and other 
factors.
Also, be especially careful of loads such 
as those listed below.
(1) When used for AC load-operating and 
the operating phase is synchronous. 
Rocking and fusing can easily occur due 
to contact shifting.
(2) Highly frequent load-operating
When highly frequent opening and 
closing of the relay is performed with a 
load that causes arcs at the contacts, 
nitrogen and oxygen in the air is fused by 
the arc energy and HNO
3
 is formed. This 
can corrode metal materials.
Three countermeasures for these are 
listed here.
• Incorporate an arc-extinguishing circuit.
• Lower the operating frequency
• Lower the ambient humidity
4) Minimum switching capacity is a 
guideline as to the lowest possible level 
at which it will be possible for a low level 
load to allow switching. This value can 
change due to the switching frequency, 
environmental conditions, and desired 
reliability level, therefore it is 
recommended to check this with the 
actual load.
5) Heat, smoke, and even a fire may 
occur if the relay is used in conditions 
outside of the allowable ranges for the 
coil ratings, contact ratings, operating 
cycle lifetime, and other specifications. 
Therefore, do not use the relay if these 
ratings are exceeded.
6) If the relay has been dropped, the 
appearance and characteristics should 
always be checked before use.
7) Incorrect wiring may cause 
unexpected events or the generation of 
heat or flames.
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation 
when used at 
temperatures 
higher than 
0
°
C
32
°
F
)
(Avoid freezing 
when used at 
temperatures 
lower than 
0
°
C
32
°
F
)
85
0
-40
+185
+32
-40
Temperature, 
°
C
°
F