Panasonic SFS4L24 PCB Mount Relay 4 NO / 2 NC SFS4L24 Datenbogen

Produktcode
SFS4L24
Seite von 9
SFS
9
ds_61410_0000_en_sfs: 061008D
NOTES
For Cautions for Use, see 
1. Coil operating power
Pure DC current should be applied to the 
coil. The wave form should be 
rectangular. If it includes ripple, the ripple 
factor should be less than 5%. However, 
check it with the actual circuit since the 
characteristics may be slightly different.
2. Coil connection
When connecting coils, refer to the wiring 
diagram to prevent mis-operation or 
malfunction.
3. Cleaning
This relay is not sealed, therefore, 
immersion may cause failure. Be careful 
that flux does not overflow onto the PC 
board or penetrate inside the relay.
4. Soldering
When using automatic soldering, the 
following conditions are recommended
1) Preheating: 120
°C 
248
°F
, within 120 s 
max (PC board solder surface).
2) Soldering: 260
°C±5°C 
500
°F±41°F
within 6 s max.
5. Attach directly to the chassis or use 
a DIN rail.
(1) When attaching directly to chassis
• Use a M3.5 screw, spring washer, and 
hex nut.
• For the mounting pitch, refer to the 
dimensions.
(2) When installing on a DIN rail
• Use a 35 mm 1.378 inch wide DIN rail 
(DIN46277).
• Install and remove as shown in the 
figures below.
2) Refer to the figure below for applicable 
wire-pressed terminals. 
(You cannot use round type wire-pressed 
terminals.)
6. Other
1) If the relay has been dropped, the 
appearance and characteristics should 
always be checked before use.
2) The switching lifetime is defined under 
the standard test condition specified in 
the JIS* C 5442-1996 standard 
(temperature 15 to 35
°C 
59 to 95
°F
humidity 25 to 75%). Check this with the 
actual product as it is affected by the coil 
driving circuit, load type, activation 
frequency, activation phase, ambient 
conditions and other factors.
Also, be especially careful with loads 
such as those listed below.
(1) When used for AC load-operation and 
the operating phase is synchronous. 
Rocking and fusing can easily occur due 
to contact shifting.
(2) During high frequency on/off 
operation with certain loads, arcing may 
occur at the contacts. This can cause 
fusion to Oxygen and Nitrogen gas in the 
air creating Nitric Acid (HNO
3
) which can 
cause corrosion to the contacts.
Please see the following countermeasure 
examples:
1. Incorporate an arc-extinguishing 
circuit.
2. Lower the operating frequency
3. Lower the ambient humidity
3) For secure operations, nominal coil 
voltage should be applied. In addition, 
please note that pick-up and drop-out 
voltage will vary according to the ambient 
temperature and operating conditions.
4) Heat, smoke, and/or fire may occur if 
the relay is used outside the allowable 
ranges for the coil ratings, contact 
ratings, operating cycle lifetime, and 
other specifications. Therefore, do not 
use the relay if these ratings are 
exceeded. Also, make sure that the relay 
is wired correctly.
5) Incorrect wiring may cause false 
operation or generate heat or flames.
6) Check the ambient conditions when 
storing or transporting the relays and 
devices containing the relays. Freezing 
or condensation may occur in the relay 
causing damage. Avoid exposing the 
relays to heavy loads, or strong shock 
and vibration.
7. Usage, transport and storage 
conditions
1) Ambient temperature, humidity, and 
atmospheric pressure during usage, 
transport, and storage of the relay:
(1) Temperature: 
–40 to +85
°C 
–40 to +185
°F
(When the temperature is 70 to 80
°C, 
reduce the 6 A max. switching current by 
0.1 A/
°C.)
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the 
temperature. Use within the range 
indicated in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for 
usage, transport, and storage
2) Condensation
Condensation forms when there is a 
sudden change in temperature under 
high temperature and high humidity 
conditions. Condensation will cause 
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may 
freeze on the relay when the 
temperatures is lower than 0
°C 
32
°F
This causes problems such as sticking of 
movable parts or operational time lags.
4) At low temperature, low humidity 
environments, the plastic becomes brittle.
Please note corrections.
<When installing>
<When removing>
Pull
Screwdriver
DIN rail
Push
6.3 mm max.
3 mm min.
.248 inch max. .118 inch min.
Humidity, %R.H.
Temperature, 
°C
°F
Tolerance range
85
5
0
+85
-40
(Avoid
condensation 
when used at 
temperatures
higher than 0
°C
32
°F
)
(Avoid freezing when
used at temperatures
lower than 0
°C
32
°F
)
+32
+185
-40